MR imaging of silicone breast implants: Evaluation of prospective and retrospective interpretations and interobserver agreement

被引:11
作者
Quinn, SF
Neubauer, NM
Sheley, RC
Demlow, TA
Szumowski, J
机构
[1] Department of Radiology, Good Samaritan Hospital and Medical Center, Portland, OR 97210
[2] Department of Radiology, Oregon Health Sciences University, Portland, OR 97201
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 01期
关键词
breast; MR; prostheses; silicone;
D O I
10.1002/jmri.1880060137
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR imaging was used to evaluate the integrity of silicone breast implants in 54 women with 108 implants, MR images were interpreted by relatively inexperienced readers who tried to reproduce the experiences reported in the literature. The study examines the interobserver agreement using different diagnostic signs and the influence of experience on interpretation errors. Prospective and retrospective interpretations were compared with surgical findings at the time of explantation. Diagnostic indicators, including the linguine sign, the inverted teardrop sign, the C sign, water droplets mixed with silicone, and extracapsular globules of silicone, were evaluated for diagnostic efficacy and interobserver agreement, The prospective sensitivity and specificity were 87% and 78%, respectively, With the retrospective interpretations, the sensitivity and specificity increased to 93% and 92%, respectively, Most of the prospective false-positive interpretations were due to misinterpreting radial folds as signs of implant rupture, Six implants interpreted retrospectively as false positives had gross amounts of silicone around the implants at surgery but there were no obvious rents in the implant shells. There was fair to excellent interobserver agreement with the individual diagnostic signs except for extracapsular globules of silicone, All of the signs had specificities of greater than 90%, The sensitivities of the individual signs were less than the overall retrospective sensitivity. With experience, the sensitivity improved from 87% to 93% and the specificity improved from 78% to 92%, This study helps substantiate the use of diagnostic signs used by other authors to detect silicone loss from breast implants by MR imaging; however, questions remain as to the clinical role of MR imaging in evaluating implants for silicone loss.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 37 条
[1]   DEFINITIVE DIAGNOSIS OF BREAST IMPLANT RUPTURE USING MAGNETIC-RESONANCE-IMAGING [J].
AHN, CY ;
SHAW, WW ;
NARAYANAN, K ;
GORCZYCA, DP ;
SINHA, S ;
DEBRUHL, ND ;
BASSETT, LW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (04) :681-691
[2]   LOCAL AND SYSTEMIC EFFECTS OF DIMETHYLPOLYSILOXANE FLUID IN MICE [J].
BENHUR, N ;
BALLANTYNE, DL ;
REES, TD ;
SEIDMAN, I .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1967, 39 (04) :423-+
[3]   DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA ;
KUHLMAN, JE .
RADIOGRAPHICS, 1993, 13 (06) :1323-1336
[4]  
BILBEY JH, 1993, CAN ASSOC RADIOL J, V44, P224
[5]   A CLINICAL AND IMMUNOLOGICAL EVALUATION OF WOMEN WITH SILICONE BREAST IMPLANTS AND SYMPTOMS OF RHEUMATIC DISEASE [J].
BRIDGES, AJ ;
CONLEY, C ;
WANG, G ;
BURNS, DE ;
VASEY, FB .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (12) :929-936
[6]   SILICONE BREAST IMPLANTS - HISTORY, SAFETY, AND POTENTIAL COMPLICATIONS [J].
BRIDGES, AJ ;
VASEY, FB .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (23) :2638-2644
[7]   CONSENSUS STATEMENT ON THE RELATIONSHIP OF BREAST IMPLANTS TO CONNECTIVE-TISSUE DISORDERS [J].
BRODY, GS ;
CONWAY, DP ;
DEAPEN, DM ;
FISHER, JC ;
HOCHBERG, MC ;
LEROY, EC ;
MEDSGER, TA ;
ROBSON, MC ;
SHONS, AR ;
WEISMAN, MH .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 90 (06) :1102-1105
[8]   FACT AND FICTION ABOUT BREAST IMPLANT BLEED [J].
BRODY, GS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 60 (04) :615-616
[9]   BREAST IMPLANT RUPTURE - DIAGNOSIS WITH US [J].
CASKEY, CI ;
BERG, WA ;
ANDERSON, ND ;
SHETH, S ;
CHANG, BW ;
HAMPER, UM .
RADIOLOGY, 1994, 190 (03) :819-823
[10]   MR-IMAGING OF BREAST IMPLANTS [J].
DEANGELIS, GA ;
DELANGE, EE ;
MILLER, LR ;
MORGAN, RF .
RADIOGRAPHICS, 1994, 14 (04) :783-794