Improved quality of anorectal endoluminal ultrasonography using emulsion of dimethicone

被引:8
作者
de la Portilla, F
Ynfante, I
Fernández, A
Bejarano, D
Carranza, G
机构
[1] Hosp Juan Ramon Jimenez, Dept Gen Surg, Coloproctol Unit, Huelva 21005, Spain
[2] Hosp Juan Ramon Jimenez, Dept Hosp Pharm, Huelva 21005, Spain
[3] Hosp Juan Ramon Jimenez, Dept Surg, Huelva 21005, Spain
[4] Hosp Valme, Dept Biostat, Res Unit, Seville, Spain
关键词
endorectal ultrasonography; dimethicone; ultrasound; contrast media;
D O I
10.1007/s10350-004-6765-0
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
PURPOSE: This study was designed to show the benefits of filling echography probes with water mixed with dimethicone to preclude artifacts caused by bubbles. METHODS: One hundred consecutive healthy volunteers (42 males; mean age, 46 years; range, 17-72 years) were blindly randomized to undergo rectal ultrasonography using conventional degassed water or degassed aqueous solution made of 40 ml of water and 10 nil of dimethicone emulsion (I ml/100 mg). All examinations performed by the same surgeon-unaware of nature of filler liquid-for ten minutes, and number of rectal ultrasonographies with artifacts attributable to air bubbles was recorded. RESULTS: Endoluminal ultrasonography performed with conventional degassed water presented artifacts attributed to presence of air bubbles in 30 of 50 examinations (60 percent). When degassed aqueous solution was used, only 5 of 50 examinations showed artifacts caused by presence of air bubbles (10 percent). This difference was statistically significant (P < 0.0005). The use of conventional fluid was associated with artifacts secondary to the presence of air bubbles, adjusted odds ratio 13.5 (95 percent confidence interval, 4.56-39.88). During this experience, the solution did not damage ultrasound scanner. CONCLUSIONS: We found that use of a dimethicone-degassed water mixture is simple, not expensive, safe, effective, and may reduce frequency of sonographic distortion in presence of air bubbles.
引用
收藏
页码:1436 / 1437
页数:2
相关论文
共 3 条
[1]
MECHANISM OF ANTIFOAMING ACTION OF SIMETHICONE [J].
BRECEVIC, L ;
BOSANKILIBARDA, I ;
STRAJNAR, F .
JOURNAL OF APPLIED TOXICOLOGY, 1994, 14 (03) :207-211
[2]
Endosonography of the anal canal and rectum [J].
Kumar, A ;
Scholefield, JH .
WORLD JOURNAL OF SURGERY, 2000, 24 (02) :208-215
[3]
MUCOLYTIC-ANTIFOAM SOLUTION FOR REDUCTION OF ARTIFACTS DURING ENDOSCOPIC ULTRASONOGRAPHY - A RANDOMIZED CONTROLLED TRIAL [J].
YIENGPRUKSAWAN, A ;
LIGHTDALE, CJ ;
GERDES, H ;
BOTET, JF .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (05) :543-546