Empirical mode decomposition based ECG enhancement and QRS detection

被引:195
作者
Pal, Saurabh [1 ]
Mitra, Madhuchhanda [2 ]
机构
[1] Heritage Inst Technol, Dept Appl Elect & Instrumentat Engn, Kolkata, W Bengal, India
[2] Univ Calcutta, Dept Appl Phys, Kolkata 700073, W Bengal, India
关键词
ECG; EMD; Baseline wander; Peak correction; Power line noise; QRS detection; NEURAL-NETWORK; RECOGNITION; WAVELET;
D O I
10.1016/j.compbiomed.2011.10.012
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper an Empirical Mode Decomposition (EMD) based ECG signal enhancement and QRS detection algorithm is proposed. Being a non-invasive measurement. ECG is prone to various high and low frequency noises causing baseline wander and power line interference, which act as a source of error in QRS and other feature extraction. EMD is a fully adaptive signal decomposition technique that generates Intrinsic Mode Functions (IMF) as decomposition output. Here, first baseline wander is corrected by selective reconstruction based slope minimization technique from IMFs and then high frequency noise is removed by eliminating a noisy set of lower order IMFs with a statistical peak correction as high frequency noise elimination is accompanied by peak deformation of sharp characteristic waves. Then a set of IMFs are selected that represents QRS region and a nonlinear transformation is done for QRS enhancement. This improves detection accuracy, which is represented in the result section. Thus in this method a single fold processing of each signal is required unlike other conventional techniques. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:83 / 92
页数:10
相关论文
共 27 条
[1]   Comparing stress ECG enhancement algorithms [J].
Afonso, VX ;
Tompkins, WJ ;
Nguyen, TQ ;
Michler, K ;
Luo, S .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1996, 15 (03) :37-44
[2]   AUTOMATIC DETECTION OF ECG WAVE BOUNDARIES USING EMPIRICAL MODE DECOMPOSITION [J].
Arafat, Md. Abdullah ;
Hasan, Md. Kamrul .
2009 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1- 8, PROCEEDINGS, 2009, :461-464
[3]   RECOMMENDATIONS FOR STANDARDIZATION AND SPECIFICATIONS IN AUTOMATED ELECTROCARDIOGRAPHY - BANDWIDTH AND DIGITAL SIGNAL-PROCESSING - A REPORT FOR HEALTH-PROFESSIONALS BY AN AD HOC WRITING GROUP OF THE COMMITTEE ON ELECTROCARDIOGRAPHY AND CARDIAC ELECTROPHYSIOLOGY OF THE COUNCIL-ON-CLINICAL-CARDIOLOGY, AMERICAN-HEART-ASSOCIATION [J].
BAILEY, JJ ;
BERSON, AS ;
GARSON, A ;
HORAN, LG ;
MACFARLANE, PW ;
MORTARA, DW ;
ZYWIETZ, C .
CIRCULATION, 1990, 81 (02) :730-739
[4]   ECG signal denoising and baseline wander correction based on the empirical mode decomposition [J].
Blanco-Velasco, Manuel ;
Weng, Binwei ;
Barner, Kenneth E. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (01) :1-13
[5]   Real time electrocardiogram QRS detection using combined adaptive threshold [J].
Christov, Ivaylo I. .
BIOMEDICAL ENGINEERING ONLINE, 2004, 3 (1)
[6]   One-pass training of optimal architecture auto-associative neural network for detecting ectopic beats [J].
Clifford, G ;
Tarassenko, L ;
Townsend, N .
ELECTRONICS LETTERS, 2001, 37 (18) :1126-1127
[7]   AN APPROACH TO CARDIAC-ARRHYTHMIA ANALYSIS USING HIDDEN MARKOV-MODELS [J].
COAST, DA ;
STERN, RM ;
CANO, GG ;
BRILLER, SA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (09) :826-836
[8]   A new mathematical based QRS detector using continuous wavelet transform [J].
Ghaffarl, A. ;
Golbayani, H. ;
Ghasemi, M. .
COMPUTERS & ELECTRICAL ENGINEERING, 2008, 34 (02) :81-91
[9]   QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE [J].
HAMILTON, PS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1157-1165
[10]  
HUANG N, 2005, HILBERTHUANG TRANSFO