In vitro validation of computational fluid dynamic simulation in human proximal airways with hyperpolarized 3He magnetic resonance phase-contrast velocimetry

被引:72
作者
de Rochefort, Ludovic
Vial, Laurence
Fodil, Redouane
Maitre, Xavier
Louis, Bruno
Isabey, Daniel
Caillibotte, Georges
Thiriet, Marc
Bittoun, Jacques
Durand, Emmanuel
Sbirlea-Apiou, Gabriela
机构
[1] Ctr Rech Claude Delorme, Air Liquide Res Ctr, F-78354 Jouy En Josas, France
[2] Univ Paris Sud, CNRS, U2R2M, F-94275 Le Kremlin Bicetre, France
[3] Univ Paris 06, CNRS, UMR 7598, Lab Jacques Louis Lions, Paris, France
[4] Univ Paris 12, INSERM, UMR 651, Creteil, France
关键词
tracheobronchial tree; patient-based geometry; airway velocity profiles;
D O I
10.1152/japplphysiol.01610.2005
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
Computational fluid dynamics (CFD) and magnetic resonance (MR) gas velocimetry were concurrently per-formed to study airflow in the same model of human proximal airways. Realistic in vivo-based human airway geometry was segmented from thoracic computed tomography. The three-dimensional numerical description of the airways was used for both generation of a physical airway model using rapid prototyping and mesh generation for CFD simulations. Steady laminar inspiratory experiments (Reynolds number Re = 770) were performed and velocity maps down to the fourth airway generation were extracted from a new velocity mapping technique based on MR velocimetry using hyperpolarized He-3 gas. Full two-dimensional maps of the velocity vector were measured within a few seconds. Numerical simulations were carried out with the experimental flow conditions, and the two sets of data were compared between the two modalities. Flow distributions agreed within 3%. Main and secondary flow velocity intensities were similar, as were velocity convective patterns. This work demonstrates that experimental and numerical gas velocity data can be obtained and compared in the same complex airway geometry. Experiments validated the simulation platform that integrates patient-specific airway reconstruction process from in vivo thoracic scans and velocity field calculation with CFD, hence allowing the results of this numerical tool to be used with confidence in potential clinical applications for lung characterization. Finally, this combined numerical and experimental approach of flow assessment in realistic in vivo-based human airway geometries confirmed the strong dependence of airway flow patterns on local and global geometrical factors, which could contribute to gas mixing.
引用
收藏
页码:2012 / 2023
页数:12
相关论文
共 45 条
[1]
ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
A MODEL STUDY OF FLOW DYNAMICS IN HUMAN CENTRAL AIRWAYS .1. AXIAL VELOCITY PROFILES [J].
CHANG, HK ;
ELMASRY, OA .
RESPIRATION PHYSIOLOGY, 1982, 49 (01) :75-95
[4]
Choukeife J, 2003, P 11 ANN M ISMRM TOR, P1391
[5]
Replication of human tracheobronchial hollow airway models using a selective laser sintering rapid prototyping technique [J].
Clinkenbeard, RE ;
Johnson, DL ;
Parthasarathy, R ;
Altan, MC ;
Tan, KH ;
Park, SM ;
Crawford, RH .
AIHAJ, 2002, 63 (02) :141-150
[6]
Flow structures and particle deposition patterns in double-bifurcation airway models. Part 1. Air flow fields [J].
Comer, JK ;
Kleinstreuer, C ;
Zhang, Z .
JOURNAL OF FLUID MECHANICS, 2001, 435 :25-54
[7]
In vitro experiments and numerical simulations of airflow in realistic nasal airway geometry [J].
Croce, Celine ;
Fodil, Redouane ;
Durand, Marc ;
Sbirlea-Apiou, Gabriela ;
Caillibotte, Georges ;
Papon, Jean-Francois ;
Blondeau, Jean-Robert ;
Coste, Andre ;
Isabey, Daniel ;
Louis, Bruno .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (06) :997-1007
[8]
Phase-contrast velocimetry with hyperpolarized 3He for in vitro and in vivo characterization of airflow [J].
de Rochefort, Ludovic ;
Maitre, Xavier ;
Fodil, Redouane ;
Vial, Laurence ;
Louis, Bruno ;
Isabey, Daniel ;
Croce, Celine ;
Darrasse, Luc ;
Apiou, Gabriela ;
Caillibotte, Georges ;
Bittoun, Jacques ;
Durand, Emmanuel .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1318-1325
[9]
Single-step stereolithography of complex anatomical models for optical flow measurements [J].
de Zélicourt, D ;
Pekkan, K ;
Kitajima, H ;
Frakes, D ;
Yoganathan, AP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01) :204-207
[10]
DEROCHEFORT L, 2004, ESMRMB 21 ANN M COP, P445