The thermal conductivity of CFC alternatives HFC-125 and HCFC-141b in the liquid phase

被引:27
作者
Gao, X [1 ]
Yamada, T [1 ]
Nagasaka, Y [1 ]
Nagashima, A [1 ]
机构
[1] KEIO UNIV,DEPT MECH ENGN,YOKOHAMA,KANAGAWA 223,JAPAN
关键词
CFC-alternatives; HCFC-141b; HFC-125; thermal conductivity; transient hot-wire method;
D O I
10.1007/BF01443393
中图分类号
O414.1 [热力学];
学科分类号
摘要
The liquid thermal conductivities of the CFC alternatives, HFC-125, and HCFC-141b measured by a transient hot-wire apparatus with one bare platinum wire are reported in the temperature ranges from 193 to 333 K (HFC-125, CHF2 . CF3) and from 193 to 393 K (HCFC-141b, CCl2F . CF3), in the pressure ranges from 2 to 30 MPa (HFC-125) and from 0.1 to 30 MPa (HCFC-141b), respectively. The results have been estimated to have an accurancy of +/-0.5%. The liquid thermal conductives obtained have been correlated by a polynomial of temperature and pressure which can represent the experimental results within the standard deviations of 0.49% for HFC-125 and 0.46% for HCFC-141b, respectively.
引用
收藏
页码:279 / 292
页数:14
相关论文
共 21 条
[1]  
ASSAEL MJ, COMMUNICATION
[2]  
BIVENS DB, 1993, P ASHRAE NIST REFR C, P73
[3]  
FELLOWS BR, 1990, THERMAL CONDUCTIVITY, V21, P311
[4]  
GROSS U, IN PRESS
[5]  
GUROVA AN, COMMUNICATION
[6]   THEORY OF TRANSIENT HOT-WIRE METHOD FOR MEASURING THERMAL-CONDUCTIVITY [J].
HEALY, JJ ;
DEGROOT, JJ ;
KESTIN, J .
PHYSICA B & C, 1976, 82 (02) :392-408
[7]  
Kobayashi Y., 1993, HIGH TEMP HIGH PRESS, V25, P253
[8]   ABSOLUTE MEASUREMENT OF THE THERMAL-CONDUCTIVITY OF ELECTRICALLY CONDUCTING LIQUIDS BY THE TRANSIENT HOT-WIRE METHOD [J].
NAGASAKA, Y ;
NAGASHIMA, A .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (12) :1435-1440
[9]  
Nagasaka Y, 1981, T JSME, V47, P821
[10]   THERMAL-CONDUCTIVITY OF R134A AND R141B WITHIN THE TEMPERATURE-RANGE 240-307-K AT THE SATURATION VAPOR-PRESSURE [J].
PAPADAKI, M ;
SCHMITT, M ;
SEITZ, A ;
STEPHAN, K ;
TAXIS, B ;
WAKEHAM, WA .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1993, 14 (02) :173-181