A novel approach for precise simulation of the EMG signal detected by surface electrodes

被引:205
作者
Farina, D
Merletti, R [1 ]
机构
[1] Politecn Torino, Dept Elect, Ctr Bioingn, I-10129 Turin, Italy
[2] Ecole Cent Nantes, Dept Automat & Informat Appl, Nantes, France
关键词
electromyography; EMG modeling; end of fiber effect; Radon transform; spectral dips;
D O I
10.1109/10.923782
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a new electromyogram generation and detection model. The volume conductor is described as a nonhomogeneous (layered) and anisotropic medium constituted by muscle, fat and skin tissues. The surface potential detected in space domain is obtained from the application of a two-dimensional spatial filter to the input current density source. The effects of electrode configuration, electrode size and inclination of the fibers with respect to the detection system are included in the transfer function of the filter. Computation of the signal in space domain is performed by applying the Radon transform; this permits to draw considerations about spectral dips and clear misunderstandings in previous theoretical derivations. The effects of generation and extinction of the action potentials at the fiber end plate and at the tendons are included by modeling the source current, without any approximation of its shape, as a function of space and time and by using again the Radon transform. The approach, based on the separation of the temporal and spatial properties of the muscle fiber action potential and of the volume conductor, includes the capacitive tissue properties.
引用
收藏
页码:637 / 646
页数:10