Hemoglobin correction for near-infrared pH determination in lysed blood solutions

被引:4
作者
Alam, MK
Franke, JE
Rohrscheib, MR
Nunez, D
Abate, V
Maynard, JD
Kemeny, GJ
机构
[1] Sandia Natl Labs, Chem & Biol Sensing Imaging & Anal Dept, Albuquerque, NM 87185 USA
[2] InLight Solut, Albuquerque, NM 87106 USA
关键词
blood pH; near-infrared spectroscopy; NIR spectroscopy; hemoglobin;
D O I
10.1366/00037020360695955
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The near-infrared (NIR) measurement of blood pH relies on the spectral signature of histidine residing on the hemoglobin molecule. If the amount of hemoglobin in solution varies, the size of the histidine signal can vary depending on changes in either the pH or hemoglobin concentration. Multivariate calibration models developed using the NIR spectra collected from blood at a single hemoglobin concentration are shown to predict data from different hemoglobin levels with a bias and slope. A simple, scalar path length correction of the spectral data does not correct this problem. However, global partial least-square (PLS) models built with data encompassing a range of hemoglobin concentration have a cross-validated standard error of prediction (CVSEP) similar to the CVSEP of data obtained from a single hemoglobin level. It will be shown that the prediction of pH of an unknown sample using a global PLS model requires that the unknown have a hemoglobin concentration failing within the range encompassed by the global model. An alternative method for correcting the predicted pH for hemoglobin levels is also presented. The alternative method updates the single-hemoglobin-level models with slope and intercept estimates from the pH predictions of data collected at alternate hemoglobin levels. The slope and intercept correction method gave SEP values averaging to 0.034 pH units. Since both methods require some knowledge of the hemoglobin concentration in order for a pH prediction to be made, a model for hemoglobin concentration is developed using spectral data and is used for pH correction.
引用
收藏
页码:1093 / 1099
页数:7
相关论文
共 11 条
[1]   Characterization of pH variation in lysed blood by near-infrared spectroscopy [J].
Alam, MK ;
Franke, JE ;
Niemczyk, TM ;
Maynard, JD ;
Rohrscheib, MR ;
Robinson, MR ;
Eaton, RP .
APPLIED SPECTROSCOPY, 1998, 52 (03) :393-399
[2]   Measurement of pH in whole blood by near-infrared spectroscopy [J].
Alam, MK ;
Rohrscheib, MR ;
Franke, JE ;
Niemczyk, TM ;
Maynard, JD ;
Robinson, MR .
APPLIED SPECTROSCOPY, 1999, 53 (03) :316-324
[3]   NEAR-INFRARED STUDIES OF STRUCTURE OF WATER .1. PURE WATER [J].
BUIJS, K ;
CHOPPIN, GR .
JOURNAL OF CHEMICAL PHYSICS, 1963, 39 (08) :2035-&
[4]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[5]  
Kuenstner JT., 1994, J Near Infrared Spetrosc, V2, P59, DOI [10.1255/jnirs.32, DOI 10.1255/JNIRS.32]
[6]  
LEHNINGER AL, 1982, PRINCIPLES BIOCH, P188
[7]   Continuous measurement of gut pH with near-infrared spectroscopy during hemorrhagic shock [J].
Puyana, JC ;
Soller, BR ;
Zhang, SB ;
Heard, SO .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 46 (01) :9-14
[8]  
SIGAARDANDERSON O, 1966, ANN NY ACAD SCI, V133, P41
[9]   Feasibility of non-invasive measurement of tissue pH using near-infrared reflectance spectroscopy [J].
Soller, BR ;
Micheels, RH ;
Coen, J ;
Parikh, B ;
Chu, L ;
Hsi, C .
JOURNAL OF CLINICAL MONITORING, 1996, 12 (05) :387-395
[10]   Partial least-squares modeling of near-infrared reflectance data for noninvasive in vivo determination of deep-tissue pH [J].
Zhang, SB ;
Soller, BR ;
Micheels, RH .
APPLIED SPECTROSCOPY, 1998, 52 (03) :400-406