Complement activation by cellulose: investigation of the effects of time, area, flow rate, shear rate and temperature on C3a generation in vitro, using a parallel plate flow cell

被引:6
作者
Lamba, NMK [1 ]
Gaylor, JDS
Courtney, JM
Lowe, GDO
机构
[1] Univ Strathclyde, Bioengn Unit, Glasgow G4 ONW, Lanark, Scotland
[2] Univ Glasgow, Glasgow Royal Infirm, Dept Med, Glasgow, Lanark, Scotland
关键词
D O I
10.1023/A:1013287614418
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development and utilization of a parallel plate flow system to study the blood response to flat sheet biomaterials, is described. Unlike most other parallel plate flow systems, which have been used to study cellular interactions with biomaterials, the controlled flow test cell described below employs the test materials on both sides of the channel through which the blood flows. The flow cell is used to conduct an investigation into the in vitro generation of C3a by a regenerated cellulose membrane, Cuprophan. The effects of experimental variables such as temperature, blood flow rate, contact area and wall shear rate on C3a generation by Cuprophan were studied. The results show that C3a generation by Cuprophan is lower at 12 degrees C than at 22 degrees C, which is in turn lower than C3a generation at 37 degrees C. Furthermore, a decrease in contact area, and increase in wall shear rate and blood flow rate, can produce a decrease in C3a concentration.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 22 条
[1]   PHYSICAL AND HYDRODYNAMIC FACTORS AFFECTING ERYTHROCYTE ADHESION TO POLYMER SURFACES [J].
CHANG, G ;
ABSOLOM, DR ;
STRONG, AB ;
STUBLEY, GD ;
ZINGG, W .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (01) :13-29
[2]   COMPLEMENT ACTIVATION DURING HEMODIALYSIS - LABORATORY EVALUATION OF HEMODIALYZERS [J].
CHENOWETH, DE ;
HENDERSON, LW .
ARTIFICIAL ORGANS, 1987, 11 (02) :155-162
[3]   BIOMATERIALS FOR BLOOD-CONTACTING APPLICATIONS [J].
COURTNEY, JM ;
LAMBA, NMK ;
SUNDARAM, S ;
FORBES, CD .
BIOMATERIALS, 1994, 15 (10) :737-744
[4]  
FRIEDMAN LI, 1971, FED PROC, V30, P1641
[5]  
GOLDMAN M, 1987, LIFE SUPPORT SYST, V5, P317
[6]  
GOLDSMITH HL, 1986, THROMB HAEMOSTASIS, V55, P415
[7]  
HELESHAW JS, 1898, NATURE, V588, P556
[8]   IN-VITRO EVALUATION OF PLATELET/BIOMATERIAL INTERACTIONS IN AN EPIFLUORESCENT VIDEO MICROSCOPY COMBINED WITH A PARALLEL-PLATE FLOW CELL [J].
KAWAGOISHI, N ;
NOJIRI, C ;
SENSHU, K ;
KIDO, T ;
NAGAI, H ;
KANAMORI, T ;
SAKAI, K ;
KOYANAGI, H ;
AKUTSU, T .
ARTIFICIAL ORGANS, 1994, 18 (08) :588-595
[9]  
KLINEFELTER H F, 1984, P1
[10]  
Kooten T. G. V., 1992, J BIOMED MATER RES, V26, P725