The perturb and observe (P&O) best operation conditions are investigated in order to identify the edge efficiency performances of this most popular maximum power point tracking (MPPT) technique for photovoltaic (PV) applications. It is shown that P&O may guarantee top-level efficiency, provided that a proper predictive (by means of a parabolic interpolation of the last three operating points) and adaptive (based on the measure of the actual power) hill climbing strategy is adopted. The approach proposed is aimed at realizing, in addition to absolute best tracking performances, high robustness and promptness both,in. sunny and cloudy weather conditions. The power gain with respect to standard P&O technique is proved by means of simulation results and experimental measurements performed on a low power system. Besides the performance improvements, it is shown,that the proposed approach allows possible reduction of hardware costs of analog-to-digital (A/D) converters used in the MPPT control circuitry.
引用
收藏
页码:934 / 950
页数:17
相关论文
共 11 条
[1]   Single-phase single-stage photovoltaic generation system based on a ripple correlation control maximum power point tracking [J].
Casadei, Domenico ;
Grandi, Gabriele ;
Rossi, Claudio .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (02) :562-568
[2]   Optimization of perturb and observe maximum power point tracking method [J].
Femia, N ;
Petrone, G ;
Spagnuolo, G ;
Vitelli, M .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) :963-973
[3]  
Hohm DP, 2000, IEEE PHOT SPEC CONF, P1699, DOI 10.1109/PVSC.2000.916230
[4]   Comparative study of maximum power point tracking algorithms [J].
Hohm, DP ;
Ropp, ME .
PROGRESS IN PHOTOVOLTAICS, 2003, 11 (01) :47-62
[5]  
HSIAO YT, 2002, IND APPL C 2002 37 I, V2, P1035
[6]   An excellent operating point tracker of the solar-cell power supply system [J].
Kobayashi, K ;
Matsuo, H ;
Sekine, Y .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (02) :495-499
[7]   MPPT of photovoltaic systems using extremum-seeking control [J].
Leyva, R ;
Alonso, C ;
Queinnec, I ;
Cid-Pastor, A ;
Lagrange, D ;
Martínez-Salamero, L .
IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2006, 42 (01) :249-258
[8]   Dynamic multiphysics model for solar array [J].
Liu, SY ;
Dougal, RA .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2002, 17 (02) :285-294
[9]  
Mutoh N, 2004, IEEE IND APPLIC SOC, P2264
[10]   On the control of photovoltaic maximum power point tracker via output parameters [J].
Shmilovitz, D .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02) :239-248