Accelerating high quality bioanalytical LC/MS/MS assays using fused-core columns

被引:24
作者
Badman, Ethan R. [1 ]
Beardsley, Richard L. [1 ]
Liang, Zhenmin [1 ]
Bansal, Surendra [1 ]
机构
[1] Hoffmann La Roche Inc, Nonclin Safety, Nutley, NJ 07110 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 25期
关键词
High throughput; Bioanalysis; LC/MS/MS; Quantitation; Fused-core column; CHROMATOGRAPHY/TANDEM MASS-SPECTROMETRY; THROUGHPUT QUANTITATIVE-ANALYSIS; LIQUID-CHROMATOGRAPHY; SMALL MOLECULES; SAMPLE PREPARATION; HUMAN PLASMA; RAT PLASMA; QUANTIFICATION; SEPARATION; DISCOVERY;
D O I
10.1016/j.jchromb.2010.06.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High quality, ultra-fast bioanalytical LC/MS/MS methods were developed using short columns packed with fused-core particles and high (1.0-3.0 mL/min) flow rates. For more than two years, at flow rates up to 3.0 mL/min, using 0.33 min non-ballistic gradients, these methods were shown to provide comparable or better performance than slower assays for accuracy, precision, sensitivity, specificity, and ruggedness, and met all criteria required by the bioanalytical regulatory guidance. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2307 / 2313
页数:7
相关论文
共 23 条
[1]   Key elements of bioanalytical method validation for small molecules [J].
Bansal, Surendra ;
DeStefano, Anthony .
AAPS JOURNAL, 2007, 9 (01) :E109-E114
[2]  
BENNETT P, 2003, P 2003 AAPS ANN M EX
[3]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[4]  
2-0
[5]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[6]   Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure [J].
Cunliffe, Jennifer M. ;
Maloney, Todd D. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) :3104-3109
[7]   A high-throughput LC-MS/MS method for the quantitation of posaconazole in human plasma: Implementing fused core silica liquid chromatography [J].
Cunliffe, Jennifer M. ;
Noren, Carl F. ;
Hayes, Roger N. ;
Clement, Robert P. ;
Shen, Jim X. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (01) :46-52
[8]  
DE NARDI C, 2006, RAPID COMMUN MASS SP, V20, P2709
[9]   Optimizing an ultrafast generic high-performance liquid chromatography/tandem mass spectrometry method for faster discovery pharmacokinetic sample throughput [J].
Dunn-Meynell, KW ;
Wainhaus, S ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (20) :2905-2910
[10]  
GIBBONS J, 2008, COMMUNICATION