Inter-trial and test-retest reliability of kinematic and kinetic gait parameters among subjects with adolescent idiopathic scoliosis

被引:26
作者
Fortin, Carole [1 ,2 ]
Nadeau, Sylvie [2 ,3 ]
Labelle, Hubert [2 ,4 ]
机构
[1] CHU St Justine, Ctr Rech, LAVIANE Lab, Montreal, PQ H3T 1C5, Canada
[2] Univ Montreal, Ecole Readaptat, Fac Med, Montreal, PQ, Canada
[3] Ctr Rech Interdisciplinaire Readaptat Montreal M, Site Inst Readaptat Montreal, Montreal, PQ, Canada
[4] Chu St Justine, Ctr Rech, Montreal, PQ H3T 1C5, Canada
关键词
gait analysis; adolescent idiopathic scoliosis; reliability; kinematics; kinetics; generalizability theory;
D O I
10.1007/s00586-007-0469-9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Gait analysis is actually used in subjects with scoliosis to determine the change in lower limb parameters after surgery, but the reliability of these parameters still remained unknown. The purpose of this study was to assess the repeatability of traditional gait parameters in subjects with adolescent idiopathic scoliosis (AIS) and to estimate the associated standard error of measurement (SEM). A test - retest design was used to assess the reliability of gait parameters at self-selected and fast speeds. A convenience sample of 20 girls aged from 12 to 17 years, with an idiopathic scoliosis (King classification: types I, II or III; Cobb angle 17 - 50 degrees) participated in the study. Five good trials were recorded on two occasions. The time-distance, kinematic, and kinetic gait parameters were recorded using foot-switches in combination with a three-dimensional motion analysis system (Optotrak) and Advanced Mechanical Technologies Inc., (AMTI) Watertown, MA, USA; force plates. The coefficients of dependability and SEM derived from the generalizability theory were used to assess the reliability. Inter-trial reliability was good for time-distance, kinematic, and kinetic (absolute and normalized) gait parameters except for the medio-lateral ground reaction force (GRF) component and the ankle dorsiflexor moment (phi=0.60 - 0.77). Test - retest reliability was higher for the kinetic than for the kinematic parameters. These coefficients ranged from 0.42 to 0.58 for the time-distance parameters; from 0.55 to 0.88 for the angular displacements and from 0.25 to 0.99 for the kinetic parameters. The SEMs were lower than 3.3 degrees for the angular displacements and lower than 8 Nm (0.15 Nm/kg) and 36 W (0.54 W/Kg) for the joint moments and powers regardless of the speed. Several gait parameters are reliable among subjects with AIS and can be used to assess the evolution of the spinal modifications and the impact of treatment on their lower limb gait pattern.
引用
收藏
页码:204 / 216
页数:13
相关论文
共 36 条
[1]
Simultaneous bilateral 3-D able-bodied gait [J].
Allard, P ;
Lachance, R ;
Aissaoui, R ;
Duhaime, M .
HUMAN MOVEMENT SCIENCE, 1996, 15 (03) :327-346
[2]
[Anonymous], 2000, Foundations of clinical research: applications to practice
[3]
[Anonymous], 1990, BIOMECHANICS MOTOR C, P75
[4]
CHANGES IN THE GAIT PATTERNS OF GROWING CHILDREN [J].
BECK, RJ ;
ANDRIACCHI, TP ;
KUO, KN ;
FERMIER, RW ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1981, 63 (09) :1452-1457
[5]
Burwell R G, 1992, Acta Orthop Belg, V58 Suppl 1, P33
[6]
LOW-FREQUENCY SELF-GENERATED VIBRATION DURING AMBULATION IN NORMAL MEN [J].
CAPPOZZO, A .
JOURNAL OF BIOMECHANICS, 1982, 15 (08) :599-609
[7]
The repeatablity of spinal motion of normal and scoliotic adolescents during walking [J].
Chan, Pui Yee ;
Wong, Hee Kit ;
Goh, James Cho Hong .
GAIT & POSTURE, 2006, 24 (02) :219-228
[8]
The influence of walking speed on mechanical joint power during gait [J].
Chen, IH ;
Kuo, KN ;
Andriacchi, TP .
GAIT & POSTURE, 1997, 6 (03) :171-176
[9]
The postural stability control and gait pattern of idiopathic scoliosis adolescents [J].
Chen, PQ ;
Wang, JL ;
Tsuang, YH ;
Liao, TL ;
Huang, PI ;
Hang, YS .
CLINICAL BIOMECHANICS, 1998, 13 :S52-S58
[10]
Crick J, 1983, MANUAL GENOVA GEN AN