Assay of ochratoxin A in wine and beer by high-pressure liquid chromatography photodiode array and gas chromatography mass selective detection

被引:168
作者
Soleas, GJ
Yan, J
Goldberg, DM
机构
[1] Liquor Control Board Ontario, Qual Assurance Dept, Toronto, ON M5E 1A4, Canada
[2] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON M5G 1L5, Canada
关键词
ochratoxin A; wine; beer; high-pressure liquid chromatography photodiode array; detector; gas chromatography-mass spectrometry; BSTFA;
D O I
10.1021/jf0100651
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
To routinely assay the concentrations of ochratoxin A (OTA) in wines and beers, two new methods were developed and evaluated. The first utilized solid-phase extraction on a C-18 cartridge to achieve a 100-fold sample concentration followed by high-performance liquid chromatography on a Cls column with gradient elution and quantitation at 333 nm by means of a photodiode array detector. Positive confirmation can be carried out by purity and match-factor analysis as well as peak shift following esterification with BF3. Total run time is 28 min. The limits of detection (LOD) and quantitation (LOQ) are 0.05 and 0.10 mug/L, respectively. Recovery and imprecision-ranged from 83 to 94% and from 4.0 to 8.9%, respectively. With a throughput of 35 assays per working day, this method is ideal for routine OTA analysis. It was used to survey the concentrations of OTA in 942 wines (2 of which gave values between 0.1 and 0.2 mug/L) and 107 beers (2 of which gave values between 0.05 and 0.1 mug/L): OTA was detected more frequently in red than white wines, with the highest incidence in red wines from Spain and Argentina. There was no association between OTA and country of origin or beverage type among the beers analyzed. The second method utilized gas chromatography with mass selective detection monitoring eight specific ions, preceded by extraction in dichloromethane and derivatization with bis[trimethylsilyl]trifluoroacetamide. LOD and LOQ were 0.1 and 2 mug/L, respectively; recovery and imprecision were 69-75 and 9.0-11.1%, respectively. The method is not suitable for routine quantitation but is potentially useful as a confirmatory tool:for samples with OTA greater than or equal to0.1 mug/L.
引用
收藏
页码:2733 / 2740
页数:8
相关论文
共 53 条
[1]   Column liquid chromatography electrospray ionisation tandem mass spectrometry for the analysis of ochratoxin [J].
Becker, M ;
Degelmann, P ;
Herderich, M ;
Schreier, P ;
Humpf, HU .
JOURNAL OF CHROMATOGRAPHY A, 1998, 818 (02) :260-264
[2]   Regional selectivity to ochratoxin A, distribution and cytotoxicity in rat brain [J].
Belmadani, A ;
Tramu, G ;
Betbeder, AM ;
Steyn, PS ;
Creppy, EE .
ARCHIVES OF TOXICOLOGY, 1998, 72 (10) :656-662
[3]   Selective toxicity of ochratoxin A in primary cultures from different brain regions [J].
Belmadani, A ;
Steyn, PS ;
Tramu, G ;
Betbeder, AM ;
Baudrimont, I ;
Creppy, EE .
ARCHIVES OF TOXICOLOGY, 1999, 73 (02) :108-114
[4]   Subchronic effects of ochratoxin A on young adult rat brain and partial prevention by aspartame, a sweetener [J].
Belmadani, A ;
Tramu, G ;
Betbeder, AM ;
Creppy, EE .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1998, 17 (07) :380-386
[5]  
Blank R., 1999, Ubersichten zur Tierernahrung, V27, P123
[6]   Cytotoxicity of nephrotoxic fungal toxins to kidney-derived LLC-PK1 and OK cell lines [J].
Bondy, GS ;
Armstrong, CL .
CELL BIOLOGY AND TOXICOLOGY, 1998, 14 (05) :323-332
[7]  
Burdaspal P. A., 1999, ALIMENTARIA, V36, P107
[8]  
Castegnaro M, 1998, INT J CANCER, V77, P70, DOI 10.1002/(SICI)1097-0215(19980703)77:1&lt
[9]  
70::AID-IJC12&gt
[10]  
3.0.CO