An automated calibration method for non-see-through head mounted displays

被引:14
作者
Gilson, Stuart J. [1 ]
Fitzgibbon, Andrew W. [2 ]
Glennerster, Andrew [3 ]
机构
[1] Univ Oxford, Dept Physiol Anat & Genet, Oxford, England
[2] Microsoft Res Ltd, Cambridge, England
[3] Univ Reading, Sch Psychol & Clin Language Sci, Reading, Berks, England
基金
英国惠康基金;
关键词
Head mounted display; Non-see-through; Calibration; Photogrammetry; Immersive virtual reality;
D O I
10.1016/j.jneumeth.2011.05.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate calibration of a head mounted display (HMD) is essential both for research on the visual system and for realistic interaction with virtual objects. Yet, existing calibration methods are time consuming and depend on human judgements, making them error prone, and are often limited to optical see-through HMDs. Building on our existing approach to HMD calibration Gilson et al. (2008), we show here how it is possible to calibrate a non-see-through HMD. A camera is placed inside a HMD displaying an image of a regular grid, which is captured by the camera. The HMD is then removed and the camera, which remains fixed in position, is used to capture images of a tracked calibration object in multiple positions. The centroids of the markers on the calibration object are recovered and their locations re-expressed in relation to the HMD grid. This allows established camera calibration techniques to be used to recover estimates of the HMD display's intrinsic parameters (width, height, focal length) and extrinsic parameters (optic centre and orientation of the principal ray). We calibrated a HMD in this manner and report the magnitude of the errors between real image features and reprojected features. Our calibration method produces low reprojection errors without the need for error-prone human judgements. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:328 / 335
页数:8
相关论文
共 16 条
[1]  
[Anonymous], 2001, MULTIPLE VIEW GEOMET
[2]   Recent advances in augmented reality [J].
Azuma, R ;
Baillot, Y ;
Behringer, R ;
Feiner, S ;
Julier, S ;
MacIntyre, B .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 2001, 21 (06) :34-47
[3]   Spatial calibration of an optical see-through head-mounted display [J].
Gilson, Stuart J. ;
Fitzgibbon, Andrew W. ;
Glennerster, Andrew .
JOURNAL OF NEUROSCIENCE METHODS, 2008, 173 (01) :140-146
[4]   Humans ignore motion and stereo cues in favor of a fictional stable world [J].
Glennerster, A ;
Tcheang, L ;
Gilson, SJ ;
Fitzgibbon, AW ;
Parker, AJ .
CURRENT BIOLOGY, 2006, 16 (04) :428-432
[5]   A four-step camera calibration procedure with implicit image correction [J].
Heikkila, J ;
Silven, O .
1997 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, 1997, :1106-1112
[6]   HMD Calibration and Its Effects on Distance Judgments [J].
Kuhl, Scott A. ;
Thompson, William B. ;
Creem-Regehr, Sarah H. .
ACM TRANSACTIONS ON APPLIED PERCEPTION, 2009, 6 (03)
[7]   Convergence properties of the Nelder-Mead simplex method in low dimensions [J].
Lagarias, JC ;
Reeds, JA ;
Wright, MH ;
Wright, PE .
SIAM JOURNAL ON OPTIMIZATION, 1998, 9 (01) :112-147
[8]   Gaze angle: a possible mechanism of visual stress in virtual reality headsets [J].
Mon-Williams, M ;
Plooy, A ;
Burgess-Limerick, R ;
Wann, J .
ERGONOMICS, 1998, 41 (03) :280-285
[9]   BINOCULAR VISION IN A VIRTUAL WORLD - VISUAL DEFICITS FOLLOWING THE WEARING OF A HEAD-MOUNTED DISPLAY [J].
MONWILLIAMS, M ;
WANN, JP ;
RUSHTON, S .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1993, 13 (04) :387-391
[10]  
Owen CB, 2004, P IEEE ACM INT S MIX