A prospective study of the diagnostic accuracy of PillCam ESO esophageal capsule endoscopy versus conventional upper endoscopy in patients with chronic gastroesophageal reflux diseases

被引:125
作者
Eliakim, R
Sharma, VK
Yassin, K
Adler, SN
Jacob, H
Cave, DR
Sachdev, R
Mitty, RD
Hartmann, D
Schilling, D
Riemann, JF
Bar-Meir, S
Bardan, E
Fennerty, B
Eisen, G
Faigel, D
Lewis, BS
Fleischer, DE
机构
[1] Mayo Clin Scottsdale, Div Gastroenterol, Scottsdale, AZ 85259 USA
[2] Rambam Med Ctr, Haifa, Israel
[3] Bikur Holim Med Ctr, Jerusalem, Israel
[4] St Elizabeths Med Ctr, Boston, MA USA
[5] Tel Hashomer Med Ctr, Tel Hashomer, Israel
[6] Oregon Hlth & Sci Univ, Klinikum Ludwigshafen, Portland, OR 97201 USA
[7] Mt Sinai Med Ctr, New York, NY 10029 USA
关键词
capsule endoscopy; esophagus; esophageal diseases; gastroesophageal reflux disease; Barrett's esophagus;
D O I
10.1097/01.mcg.0000170764.29202.24
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Introduction: Endoscopy is commonly performed to evaluate for suspected or established esophageal diseases including gastroesophageal reflux disease (GERD) and its complications. The newly developed PillCam ESO Esophageal Capsule offers an alternative approach to visualize the esophagus and to evaluate patients with suspected esophageal disease. Aim: Compare the accuracy (specificity, sensitivity, positive predictive value [PPV], and negative predictive value [NPV]) of esophageal capsule endoscopy (ECE) compared with esophagogastroduodenoscopy (EGD) in evaluating patients with GERD. Methods: A multicenter pivotal trial was conducted at seven sites. The PillCam ESO esophageal capsule is similar to the standard capsule endoscope used for the small bowel but acquires video images from both ends of the device at 2 frames/second/end. A total of 106 patients (93 GERD; 13 Barrett) underwent ECE followed by EGD. ECE videos were evaluated by an investigator blinded to EGD findings. A blinded adjudication committee reviewed all discrepant findings between ECE and EGD. Results: Sixty-six of 106 patients had positive esophageal findings, ECE identified esophageal abnormalities in 61 (sensitivity, 92%; specificity, 95%). The per-protocol sensitivity, specificity, PPV, and NPV of ECE for Barrett esophagus were 97%, 99%, 97%, and 99%, respectively, and for esophagifs 89%, 99%, 97%, and 94%, respectively. ECE was preferred over EGD by all patients. There were no adverse events related to ECE. Conclusions: ECE is a convenient and sensitive method for visualization of esophageal mucosal pathology and may provide an effective method to evaluate patients for esophageal disease.
引用
收藏
页码:572 / 578
页数:7
相关论文
共 14 条
  • [1] RESULTS FROM THE AMERICAN SOCIETY FOR GASTROINTESTINAL ENDOSCOPY UNITED-STATES FOOD AND DRUG ADMINISTRATION COLLABORATIVE STUDY ON COMPLICATION RATES AND DRUG-USE DURING GASTROINTESTINAL ENDOSCOPY
    ARROWSMITH, JB
    GERSTMAN, BB
    FLEISCHER, DE
    BENJAMIN, SB
    [J]. GASTROINTESTINAL ENDOSCOPY, 1991, 37 (04) : 421 - 427
  • [2] Bytzer P, 1999, AM J GASTROENTEROL, V94, P86
  • [3] Devesa SS, 1998, CANCER, V83, P2049, DOI 10.1002/(SICI)1097-0142(19981115)83:10<2049::AID-CNCR1>3.3.CO
  • [4] 2-U
  • [5] A novel diagnostic tool for detecting oesophageal pathology: the PillCam oesophageal video capsule
    Eliakim, R
    Yassin, K
    Shlomi, I
    Suissa, A
    Eisen, GM
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2004, 20 (10) : 1083 - 1089
  • [6] Holtmann G, 2001, EUR J GASTROEN HEPAT, V13, pS5
  • [7] Neu B, 2003, ENDOSCOPY, V35, P957
  • [8] INCREASING INCIDENCE OF ADENOCARCINOMA OF THE ESOPHAGUS AND ESOPHAGOGASTRIC JUNCTION
    PERA, M
    CAMERON, AJ
    TRASTEK, VF
    CARPENTER, HA
    ZINSMEISTER, AR
    [J]. GASTROENTEROLOGY, 1993, 104 (02) : 510 - 513
  • [9] Ramirez FC, 2004, GASTROINTEST ENDOSC, V59, pAB145
  • [10] Digestive and liver diseases statistics, 2004
    Russo, MW
    Wei, JT
    Thiny, MT
    Gangarosa, LM
    Brown, A
    Ringel, Y
    Shaheen, NJ
    Sandler, RS
    [J]. GASTROENTEROLOGY, 2004, 126 (05) : 1448 - 1453