Paucity of studies to support that abnormal coagulation test results predict bleeding in the setting of invasive procedures: an evidence-based review

被引:486
作者
Segal, JB
Dzik, WH
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD 21205 USA
[2] Massachusetts Gen Hosp, Blood Transfus Serv, Boston, MA 02114 USA
关键词
D O I
10.1111/j.1537-2995.2005.00546.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The literature was systematically reviewed to determine whether a prolonged prothrombin time or elevated international normalized ratio predicts bleeding during invasive diagnostic procedures. STUDY DESIGN AND METHODS: MEDLINE and CENTRAL were searched through August 2004, with no language restriction, and reference lists were reviewed. For inclusion, articles must have reported on bleeding in more than five patients with abnormal test results undergoing diagnostic procedures. RESULTS: One trial and 24 observational studies were included. In 2 studies of bronchoscopy, the bleeding rates were similar among those with normal and abnormal tests, with wide confidence intervals (CIs) around the risk differences. During central vein cannulation (3 studies), bleeding rates among those with abnormal tests was unlikely to exceed 2.3 percent. The largest of 3 studies of arteriography found equivalent bleeding rates in patients with and without abnormal tests (risk difference, 0%; 95% CI, -3% to 2%). In the 3 studies of liver biopsy with plugging, bleeding rates were 0, 4, and 5 percent with the upper bounds of the CI as high as 17 percent. In the largest study of transjugular biopsy, the bleeding rate was 1.5 percent (95% CI, 0.3%-4%) in patients with abnormal tests. The highest bleeding rate in the 3 studies of percutaneous liver biopsy was 5.3 percent (95% CI, 1%-13%), similar to the rate in patients with normal test results. CONCLUSION: There is insufficient evidence to conclude that abnormal test results predict bleeding. Randomized controlled trials should be performed to provide stronger evidence for clinical decision making regarding preprocedure transfusion.
引用
收藏
页码:1413 / 1425
页数:13
相关论文
共 35 条
[1]   Does blinding of readers affect the results of meta-analyses? [J].
Berlin, JA .
LANCET, 1997, 350 (9072) :185-186
[2]  
Bird LA, 1998, S AFR MED J, V88, P1344
[3]   Transjugular liver biopsy: assessment of safety and efficacy of the Quick-Core biopsy needle [J].
Bruzzi, JF ;
O'Connell, MJ ;
Thakore, H ;
O'Keane, C ;
Crowe, J ;
Murray, JG .
ABDOMINAL IMAGING, 2002, 27 (06) :711-715
[4]  
CATURELLI E, 1993, LIVER, V13, P270
[5]   INSTRUMENTS FOR ASSESSING THE QUALITY OF DRUG STUDIES PUBLISHED IN THE MEDICAL LITERATURE [J].
CHO, MK ;
BERO, LA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (02) :101-104
[6]   Transjugular liver biopsy: modified Ross transseptal needle versus Quick-core biopsy needle [J].
Choo, SW ;
Do, YS ;
Park, KB ;
Kim, SH ;
Han, YH ;
Choo, IW .
ABDOMINAL IMAGING, 2000, 25 (05) :483-485
[7]   Evaluation of coagulation tests as predictors of angiographic bleeding complications [J].
Darcy, MD ;
Kanterman, RY ;
Kleinhoffer, MA ;
Vesely, TM ;
Picus, D ;
Hicks, ME ;
Pilgram, TK .
RADIOLOGY, 1996, 198 (03) :741-744
[8]  
DAVIS CL, 1995, J AM SOC NEPHROL, V6, P1250
[9]  
Denzer U, 2001, Z Gastroenterol, V39, P11
[10]   Central venous catheter placement in patients with disorders of hemostasis [J].
Doerfler, ME ;
Kaufman, B ;
Goldenberg, AS .
CHEST, 1996, 110 (01) :185-188