Comparison of three-dimensional hysterosalpingo-contrast-sonography and diagnostic laparoscopy with chromopertubation in the assessment of tubal patency for the investigation of subfertility

被引:48
作者
Chan, CCW [1 ]
Ng, EHY [1 ]
Tang, OS [1 ]
Chan, KKL [1 ]
Ho, PC [1 ]
机构
[1] Univ Hong Kong, Queen Mary Hosp, Dept Obstet & Gynaecol, Hong Kong, Hong Kong, Peoples R China
关键词
laparoscopy; subfertility; three-dimensional hysterosalpingo-contrast-sonography;
D O I
10.1111/j.0001-6349.2005.00797.x
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background. Two-dimensional hysterosalpingo-contrast-sonography, as a screening test for tubal patency for subfertile patients, is limited by the difficulty in visualizing the entire Fallopian tube owing to its tortuosity. This major disadvantage can be overcome by means of the three-dimensional hysterosalpingo-contrast-sonography (3D-HyCoSy). The current study compared the efficacy of 3D-HyCoSy with diagnostic laparoscopy and its feasibility as a screening test for tubal patency. Methods. Twenty-one consecutive patients scheduled to have laparoscopy were recruited to undergo the 3D-HyCoSy 2 days before the scheduled laparoscopy. Echovist((R)) (Schering AG, Berlin, Germany), the ultrasound contrast medium, was injected into the uterine cavity via a Foley's catheter. The flow of the medium in the Fallopian tube was captured by using three-dimensional power Doppler mode and was stored for later analysis. The person analyzing the images, the surgeon performing the laparoscopy, and the patients were blinded to the patients' identity and the sonography findings. The sonography and the laparoscopy findings were compared. The duration for the ultrasound examination, pain score, and patient acceptability were assessed. Results. Thirty-four of 42 (81%) Fallopian tubes were assessed. The sensitivity of 3D-HyCoSy for detecting tubal patency was 100% with a specificity of 67%. The positive and negative predictive values were 89 and 100%, respectively; the concordance rate was 91%. The mean duration (+/- SD) for the 3D-HyCoSy was 13.4 +/- 5.5 min. Fifteen patients (71%) regarded the sonography examination as at least acceptable. Conclusions. This study confirmed the feasibility of using 3D-HyCoSy as an initial investigation for tubal patency.
引用
收藏
页码:909 / 913
页数:5
相关论文
共 23 条
  • [1] Hysterosalpingo-contrast sonography (HyCoSy) using Echovist(R)-200 in the outpatient investigation of infertility patients
    Ayida, G
    Harris, P
    Kennedy, S
    Seif, M
    Barlow, D
    Chamberlain, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (826) : 910 - 913
  • [2] A comparison of patient tolerance of hysterosalpingo-contrast sonography (HyCoSy) with Echovist(R)-200 and X-ray hysterosalpingography for outpatient investigation of infertile women
    Ayida, G
    Kennedy, S
    Barlow, D
    Chamberlain, P
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1996, 7 (03) : 201 - 204
  • [3] ULTRASOUND CONTRAST HYSTEROSALPINGOGRAPHY - EVALUATION AS AN OUTPATIENT PROCEDURE
    BALEN, FG
    ALLEN, CM
    SIDDLE, NC
    LEES, WR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (787) : 592 - 599
  • [4] HYSTEROSALPINGO CONTRAST SONOGRAPHY (HYCOSY) AND ITS FUTURE-ROLE WITHIN THE INVESTIGATION OF INFERTILITY IN EUROPE
    CAMPBELL, S
    BOURNE, TH
    TAN, SL
    COLLINS, WP
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1994, 4 (03) : 245 - 253
  • [5] GENITAL CHLAMYDIAL INFECTIONS - EPIDEMIOLOGY AND REPRODUCTIVE SEQUELAE
    CATES, W
    WASSERHEIT, JN
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1991, 164 (06) : 1771 - 1781
  • [6] Dietrich M, 1996, J CLIN ULTRASOUND, V24, P523, DOI 10.1002/(SICI)1097-0096(199611/12)24:9<523::AID-JCU6>3.0.CO
  • [7] 2-P
  • [8] Can hysterosalpingocontrast-sonography replace hysterosalpingography in the assessment of tubal subfertility?
    Dijkman, AB
    Mol, BWJ
    van der Veen, F
    Bossuyt, PMM
    Hogerzeil, HV
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2000, 35 (01) : 44 - 48
  • [9] ENTRANCE SURFACE AND OVARIAN DOSES IN HYSTEROSALPINGOGRAPHY
    FIFE, IAJ
    WILSON, DJ
    LEWIS, CA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (801) : 860 - 863
  • [10] Transvaginal ultrasonography associated with colour Doppler energy in the diagnosis of hydrosalpinx
    Guerriero, S
    Ajossa, S
    Lai, MP
    Mais, V
    Paoletti, AM
    Melis, GB