Characterization of antithrombin III from human plasma by two-dimensional gel electrophoresis and capillary electrophoretic methods

被引:19
作者
Kremser, L
Brückner, A
Heger, A
Grunert, T
Buchacher, A
Josic, D
Allmaier, M
Rizzi, A
机构
[1] Univ Vienna, Inst Analyt Chem, A-1090 Vienna, Austria
[2] Octapharma Pharmazeut Produk MbH, Vienna, Austria
关键词
antithrombin III; capillary isoelectric focusing; capillary zone electrophoresis; glycoprotein microheterogeneity; two-dimensional gel electrophoresis;
D O I
10.1002/elps.200305651
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The isoforms distribution of the glycoprotein antithrombin III (ATIII) derived from human plasma was investigated by means of isoelectric focusing (IEF) in polyacrylamide gels with immobilized pH gradients (IPG) and two-dimensional gel electrophoresis (2-DE) as well as capillary electrophoretic methods. It turned out that the presence of high concentrations of chaotropics (urea, thiourea) and zwitterionic detergents (3-[(3-cholamidepropyl)dimethylammonio]-l -propanesulfonate (CHAPS)) was decisive for attaining good resolution of the protein isoforms. Resolution by IPG-IEF was obtained with excellent reproducibility and p/ differences down to 0.01 pH units could be distinguished. ATIII-alpha and ATIII-beta-fractions preseparated by heparin affinity chromatography showed an analogous but shifted spot pattern consisting each of one major and three minor isoforms. The main isoforms of ATIII-alpha and ATIII-beta exhibit p/ values of 5.18 and 5.32, respectively, both values determined in the presence of high concentrations of urea. The p/ difference of 0.14 pH units correspond to the effect of two sialic acids absent in ATIII-P. The formation and occurrence of ATIII dimers and trimers turned out to be dependent on the sample preparation. The results obtained by 2-DE were compared with those of capillary zone electrophoresis (CZE) and capillary IEF (CIEF). Quantitative analysis regarding the CZE separated isoforms of plasma derived ATIII yielded a content of about 70% ATIII-alpha main isoform and about 6.6% of ATIII-beta. The p/ values of ATIII determined by CIEF with internal calibration were in fair agreement with the p/ values of the main isoforms achieved with 2-DE.
引用
收藏
页码:4282 / 4290
页数:9
相关论文
共 29 条
[1]   Molecular mass determination of plasma-derived glycoproteins by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with internal calibration [J].
Belgacem, O ;
Buchacher, A ;
Pock, K ;
Josic, D ;
Sutton, C ;
Rizzi, A ;
Allmaier, G .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (11) :1118-1130
[2]   PHYSIOLOGICAL VARIANT OF ANTITHROMBIN-III LACKS CARBOHYDRATE SIDE-CHAIN AT ASN-135 [J].
BRENNAN, SO ;
GEORGE, PM ;
JORDAN, RE .
FEBS LETTERS, 1987, 219 (02) :431-436
[3]   High-performance capillary electrophoresis for in-process control in the production of antithrombin III and human clotting factor IX [J].
Buchacher, A ;
Schulz, P ;
Choromanski, J ;
Schwinn, H ;
Josic, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 802 (02) :355-366
[4]  
BUSBY TF, 1981, J BIOL CHEM, V256, P2140
[5]  
Carrell RW, 2001, THROMB HAEMOSTASIS, V86, P14
[6]  
Chang WSW, 1997, THROMB HAEMOSTASIS, V77, P323
[7]  
CONARD J, 1983, HAEMOSTASIS, V13, P363
[8]   ANALYSIS OF ANTITHROMBIN-III MICROHETEROGENEITY BY ISOELECTRIC-FOCUSING IN POLYACRYLAMIDE GELS AND IMMUNOBLOTTING [J].
DALY, M ;
HALLINAN, F .
THROMBOSIS RESEARCH, 1985, 40 (02) :207-214
[9]   Separation of antithrombin III variants by micellar electrokinetic chromatography [J].
Dönges, R ;
Römisch, J ;
Stauss, H ;
Brazel, D .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :307-313
[10]   Transgenically produced human antithrombin: Structural and functional comparison to human plasma-derived antithrombin [J].
Edmunds, T ;
Van Patten, SM ;
Pollock, J ;
Hanson, E ;
Bernasconi, R ;
Higgins, E ;
Manavalan, P ;
Ziomek, C ;
Meade, H ;
McPherson, JM ;
Cole, ES .
BLOOD, 1998, 91 (12) :4561-4571