More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy

被引:58
作者
Kim, Hee-June [1 ]
Park, Jaeyeong [2 ]
Shin, Ji-Yeon [3 ]
Park, Il-Hyung [1 ]
Park, Kyeong-Hyeon [1 ]
Kyung, Hee-Soo [1 ]
机构
[1] Kyungpook Natl Univ, Kyungpook Natl Univ Hosp, Sch Med, Dept Orthopaed Surg, Daegu, South Korea
[2] Yeungjin Coll, Sch Mech Engn, Daegu, South Korea
[3] Kyungpook Natl Univ, Sch Med, Dept Prevent Med, Daegu, South Korea
关键词
3D printing; High tibial osteotomy; Picture archiving and communication system; ALIGNMENT MEASUREMENT; NAVIGATION SYSTEM; VARUS DEFORMITY; CLOSED-WEDGE; RELIABILITY; OSTEOARTHRITIS; RECONSTRUCTION; GONARTHROSIS; ARTHRITIS; PLATEAU;
D O I
10.1007/s00167-018-4927-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
PurposeThe purpose of this study was to compare the accuracy of the preoperative planning method using a three-dimensional (3D) printed model with that of a method using picture archiving and communication system (PACS) images in high tibial osteotomy (HTO).MethodsPatients who underwent HTO using a 3D printed model (20 patients) and a method based on PACS images (20 patients) from 2012 to 2016 were compared. After obtaining the correction angle, in the 3D printed method, the wedge-shaped 3D printed model was designed. The PACS method used preoperative radiographs. The accuracy of HTO for each method was compared using radiographs obtained at the first postoperative year. The preoperative and postoperative posterior tibial slope angles were also compared.ResultsThe weight-bearing line was corrected 21.211.8% from preoperatively to 61.63.3% postoperatively in the 3D group and from 19.4 +/- 12.3% to 61.3 +/- 8.1% in the PACS group. The mean absolute difference with the target point was lower in the 3D group (2.3 +/- 2.5) than in the PACS group (6.2 +/- 5.1; p=0.005). The number of patients in an acceptable range was higher in the 3D group than in the PACS group. The posterior tibial slope angle was not significantly different in the 3D group (8.6 degrees-8.9 degrees), but was significantly different in the PACS group (9.9 degrees-10.5 degrees, p=0.042).ConclusionsIn open-wedge HTO, a more accurate correction for successful results could be obtained using the 3D printed model.Level of evidenceIV.
引用
收藏
页码:3452 / 3458
页数:7
相关论文
共 26 条
[1]
Results of high tibial osteotomy: review of the literature [J].
Amendola, Annunziato ;
Bonasia, Davide Edoardo .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (02) :155-160
[2]
Patellar height and the inclination of the tibial plateau after high tibial osteotomy -: The open versus the closed-wedge technique [J].
Brouwer, RW ;
Bierma-Zeinstra, SMA ;
van Koeveringe, AJ ;
Verhaar, JAN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (09) :1227-1232
[3]
UPPER TIBIAL OSTEOTOMY FOR OSTEO-ARTHRITIS [J].
COVENTRY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1136-1140
[5]
The effect of closed- and open-wedge high tibial osteotomy on tibial slope - A retrospective radiological review of 120 cases [J].
El-Azab, H. ;
Halawa, A. ;
Anetzberger, H. ;
Imhoff, A. B. ;
Hinterwimmer, S. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (09) :1193-1197
[6]
FUJISAWA Y, 1979, ORTHOP CLIN N AM, V10, P585
[7]
HERNIGOU P, 1987, J BONE JOINT SURG AM, V69A, P332
[8]
RESULTS OF PROXIMAL TIBIAL OSTEOTOMY - EFFECTS OF TIBIOFEMORAL ANGLE, STANCE-PHASE FLEXION-EXTENSION, AND MEDIAL-PLATEAU FORCE [J].
KETTELKAMP, DB ;
WENGER, DR ;
CHAO, EYS ;
THOMPSON, C .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (07) :952-960
[9]
Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone [J].
Kwun, Jun-Dae ;
Kim, Hee-June ;
Park, Jaeyoung ;
Park, Il-Hyung ;
Kyung, Hee-Soo .
KNEE, 2017, 24 (01) :16-22
[10]
Lee Dong Chul, 2012, Knee Surg Relat Res, V24, P61, DOI 10.5792/ksrr.2012.24.2.61