Criteria for the selection of materials for implanted electrodes

被引:170
作者
Geddes, LA [1 ]
Roeder, R [1 ]
机构
[1] Purdue Univ, Dept Biomed Engn, W Lafayette, IN 47907 USA
关键词
implanted electrodes; microelectrodes; stimulating electrodes; electrode arrays; electrodes;
D O I
10.1114/1.1581292
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There are four criteria that must be considered when choosing material for an implanted electrode: (1) tissue response, (2) allergic response, (3) electrode-tissue impedance, and (4) radiographic visibility. This paper discusses these four criteria and identifies the materials that are the best candidates for such electrodes. For electrodes that make ohmic contact with tissues: gold, platinum, platinum-iridium, tungsten, and tantalum are good candidates. The preferred insulating materials are polyimide and glass. The characteristics of stimulator output circuits and the importance of the bidirectional waveform in relation to electrode decomposition are discussed. The paper concludes with an analysis, the design criteria, and the special properties and materials for capacitive recording and stimulating electrodes. (C) 2003 Biomedical Engineering Society.
引用
收藏
页码:879 / 890
页数:12
相关论文
共 43 条
[1]  
Agnew W. F., 1990, NEURAL PROSTHESES
[2]  
[Anonymous], MED DEVICE ACCIDENTS
[3]  
ARONSON S, 1987, IEEE T BIOMED ENG, V32, P85
[4]   PHAGOCYTIC AND METABOLIC REACTIONS TO CHRONICALLY IMPLANTED METAL BRAIN ELECTRODES [J].
BABB, TL ;
KUPFER, W .
EXPERIMENTAL NEUROLOGY, 1984, 86 (02) :171-182
[5]   ECZEMATOUS DERMATITIS FROM NICKEL [J].
BARRANCO, VP ;
SOLOMAN, H .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1972, 220 (09) :1244-+
[6]  
BATROW J, 1963, Patent No. 3077884
[7]   CRITERIA FOR SELECTING ELECTRODES FOR ELECTRICAL-STIMULATION - THEORETICAL AND PRACTICAL CONSIDERATIONS [J].
BRUMMER, SB ;
ROBBLEE, LS ;
HAMBRECHT, FT .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) :159-171
[8]   ELECTROCHEMICAL CONSIDERATIONS FOR SAFE ELECTRICAL-STIMULATION OF NERVOUS-SYSTEM WITH PLATINUM-ELECTRODES [J].
BRUMMER, SB ;
TURNER, MJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1977, 24 (01) :59-63
[9]   A SILICON-BASED, 3-DIMENSIONAL NEURAL INTERFACE - MANUFACTURING PROCESSES FOR AN INTRACORTICAL ELECTRODE ARRAY [J].
CAMPBELL, PK ;
JONES, KE ;
HUBER, RJ ;
HORCH, KW ;
NORMANN, RA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (08) :758-768
[10]   HISTOPATHOLOGICAL CHANGES PRODUCED BY IMPLANTED ELECTRODES IN CAT BRAINS - COMPARISON WITH HISTOPATHOLOGICAL CHANGES IN HUMAN AND EXPERIMENTAL PUNCTURE WOUNDS [J].
COLLIAS, JC ;
MANUELIDIS, EE .
JOURNAL OF NEUROSURGERY, 1957, 14 (03) :302-328