External steel plate systems for the shear strengthening of reinforced concrete beams

被引:101
作者
Barnes, RA
Baglin, PS [1 ]
Mays, GC
Subedi, NK
机构
[1] Univ Dundee, Dept Civil Engn, Dundee DD1 4HN, Scotland
[2] Cranfield Univ, Royal Mil Coll Sci, Shrivenham, England
基金
英国工程与自然科学研究理事会;
关键词
retrofitted; adhesive bonding; bolting; composite beam; shear; steel plate;
D O I
10.1016/S0141-0296(00)00124-3
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Attaching steel plates to the external surfaces of concrete beams can provide a practical solution to the upgrading of existing structures. When plates are fixed to the sides (web) of a beam a large increase in the sheer capacity can be realised. The experimental results from two methods of plate attachment, namely adhesive bonding and bolting, an examined and compared. A method of analysis, based on the equilibrium of forces along the critical section, is proposed. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1162 / 1176
页数:15
相关论文
共 13 条
[1]  
[Anonymous], 1993, CEB-FIP model code 1990: Design code
[2]  
BAGLIN PS, 1998, THESIS U DUNDEE
[3]  
*BIS, 1972, CP110 BSI 1
[4]  
*BSI, 1985, 8110 BS 1
[5]  
*BSI, 1957, 114 CP BSI
[6]  
Clarke J., 1996, STRUCT ENG, V74, P283
[7]  
*ISO, 85011 ISO
[8]  
MAYS GC, 1993, BRIDGE MANAGEMENT, P2
[9]   External plate reinforcement for concrete beams [J].
Subedi, NK ;
Baglin, PS .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (12) :1490-1495
[10]   Plate reinforced concrete beams: experimental work [J].
Subedi, NK ;
Baglin, PS .
ENGINEERING STRUCTURES, 1999, 21 (03) :232-254