Preconcentration and determination of trace elements with 2-aminoacetylthiophenol functionalized Amberlite XAD-2 by inductively coupled plasma-atomic emission spectrometry

被引:150
作者
Guo, Y [1 ]
Din, BJ
Liu, YG
Chang, XJ
Meng, SM
Liu, JH
机构
[1] Xian Jiaotong Univ, Sch Mat Sci & Engn, Xian 710049, Peoples R China
[2] Yanbei Normal Inst, Dept Chem, Datong 037000, Peoples R China
[3] Lanzhou Univ, Sch Chem & Chem Engn, Lanzhou 730000, Peoples R China
关键词
preconcentration; 2-aminoacetylthiophenol; Amberlite XAD-2-AATP; water and sediment samples; inductively coupled plasma-atomic emission; spectrometry (ICP-AES);
D O I
10.1016/S0039-9140(03)00423-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
2-Aminoacetylthiophenol (AATP)-modified Amberlite XAD-2 has been synthesized by coupling it through -N=N-NH- group. The resulting chelating resin, characterized by elemental analysis, thermogravimetric analysis (TGA) and infrared (IR) spectra, was used to preconcentrate Cd, Hg, Ag. Ni. Co, Cu and Zn ions. Several parameters, such as distribution coefficient and sorption capacity of the chelating resin, pH and flow rates of uptake and striping, volume of sample and eluent, were evaluated. The effects of electrolytes and cations on the preconcentration were also investigated. The recoveries were >96%. The procedure was validated by standard addition and analysis of a standard reference sediment material (GBW 07309 China). The developed method was utilized for preconcentration and determination of Cd, Hg, Ag, Ni, Co, Cu and Zn in tap water, river water and sediment samples by inductively coupled plasma-atomic emission spectrometry (ICP-AES) with satisfactory results. The 3sigma detection limits for Cd, Hg, Ag, Ni, Co, Cu and Zn were found to be 0.10, 0.23, 0.41, 0.13, 0.25, 0.39 and 0.58 mugl(-1). respectively. The relative standard deviation of the determination was < 10%. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:209 / 215
页数:7
相关论文
共 48 条
[1]   Selective determination of cobalt using polyurethane foam and 2-(2-benzothiazolylazo)-2-p-cresol as a spectrophotometric reagent [J].
Carvalho, MS ;
Fraga, ICS ;
Neto, KCM ;
Silva, EQ .
TALANTA, 1996, 43 (10) :1675-1680
[2]   SYNTHESIS AND CHARACTERIZATION OF A MACROPOROUS POLY(VINYL-AMINOACETONE) CHELATING RESIN FOR THE PRECONCENTRATION AND SEPARATION OF TRACES OF GOLD, PALLADIUM, RHODIUM AND RUTHENIUM [J].
CHANG, XJ ;
LUO, XY ;
ZHAN, GY ;
SU, ZX .
TALANTA, 1992, 39 (08) :937-941
[3]   Efficiency and application of poly(acryldinitrophenylamidrazone-dinitroacrylphenylhydrazine) chelating fiber for pre-concentrating and separating trace Au(III), Ru(III), In(III), Bi(III), Zr(IV), V(V), Ga(III) and Ti(IV) from solution samples [J].
Chang, XJ ;
Su, QQ ;
Liang, DY ;
Wei, XJ ;
Wang, BT .
TALANTA, 2002, 57 (02) :253-261
[4]   Efficiency and mechanism of new poly (acryl-phenylamidrazone phenylhydrazide) chelating fiber for adsorbing trace Ga, In, Bi, V and Ti from solution [J].
Chang, XJ ;
Yang, XL ;
Wei, XJ ;
Wu, KB .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :231-238
[5]   BIOCATALYSIS - IMMOBILIZED CELLS AND ENZYMES [J].
CHIBATA, I ;
TOSA, T ;
SATO, T .
JOURNAL OF MOLECULAR CATALYSIS, 1986, 37 (01) :1-24
[6]   SPECTROFLUOROMETRIC DETECTION-OF ZINC AND CADMIUM WITH 8-(BENZENESULFONAMIDO)-QUINOLINE IMMOBILIZED ON A POLYMERIC MATRIX [J].
COMPANO, R ;
FERRER, R ;
GUITERAS, J ;
PRAT, MD .
ANALYST, 1994, 119 (06) :1225-1228
[7]   Applying magnesium hydroxide coprecipitation method for trace analysis to dialysis concentrate [J].
Elci, L ;
Saracoglu, S .
TALANTA, 1998, 46 (06) :1305-1310
[8]   Flow injection solid phase extraction with Chromosorb 102:: determination of lead in soil and waters by flame atomic absorption spectrometry [J].
Elçi, L ;
Arslan, Z ;
Tyson, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1109-1116
[9]  
ELCI L, 1992, J ANAL CHIM, V340, P175
[10]   Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN [J].
Ferreira, SLC ;
de Brito, CF ;
Dantas, AF ;
de Araújo, NML ;
Costa, ACS .
TALANTA, 1999, 48 (05) :1173-1177