The efficiencies of four different methods for the extraction of phospholipids (PLs) and lysophospholipids (LPLs) from human plasma samples were examined by comparing extraction recovery values using nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nLC-ESI-MS). For recovery measurements, six PL and six LPL standards of different head groups were spiked into a human plasma sample, and the peak areas of each individual species after extraction were measured from the chromatograms of the nLC-ESI-MS runs. Recovery was calculated by comparing the peak area of an extracted standard species with that of the same species' spike after extraction of the same plasma sample. For lipid extraction, four different extraction methods were examined: three based on the Folch method with different organic solvents such as CHCl3, methyl-tertbutyl ether (MTBE), and MTBE/CH3OH, and one relatively fast method involving CH3OH only. Evaluations of recovery showed that the modified Folch method with MTBE/CH3OH proposed in this study was effective for extracting most PL and LPL standards. Then, the four extraction methods were compared with the identified numbers of plasma PLs and LPLs, of which molecular structures can be confirmed by data-dependent, collision-induced dissociation experiments during nLC-ESI-MS-MS. These results demonstrated that the proposed method yielded the identification of 54 LPLs and 66 PLs from a plasma sample, which was the highest identification rate among the four methods.
引用
收藏
页码:451 / 458
页数:8
相关论文
共 31 条
[1]
Quantitative analysis of phosphatidyllcholline in rat liver tissue by nanoflow liquid chromatography/tandem mass spectrometry [J].
Ahn, Eun Jeong ;
Kim, Hanna ;
Chung, Bong Chul ;
Moon, Myeong Hee .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (16) :2598-2604
[2]
Nanoflow liquid chromatography-tandem mass spectrometry for the characterization of intact phosphatidylcholines from soybean, bovine brain, and liver [J].
Bang, DY ;
Kang, DJ ;
Moon, MH .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1104 (1-2) :222-229
[3]
BLIGH EG, 1959, CAN J BIOCHEM PHYS, V37, P911
[4]
BOUGNOUX P, 1992, BREAST CANCER RES TR, V20, P185
[5]
Brouwers JFHM, 1999, J LIPID RES, V40, P164
[6]
FOLCH J, 1957, J BIOL CHEM, V226, P497
[7]
A direct and simple method of coupling matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) to thin-layer chromatography (TLC) for the analysis of phospholipids from egg yolk [J].
Fuchs, Beate ;
Schiller, Juergen ;
Suess, Rosmarie ;
Schuerenberg, Martin ;
Suckau, Detlev .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (03) :827-834
[8]
A comparative study of the phospholipid profiles of guinea pig cardiac muscle and bullfrog cardiac and thigh skeletal muscle, and their in-vitro differential deacylation by endogenous phospholipases. Thin layer chromatographic and densitometric analysis [J].
Helmy, Fatma ;
Rothenbacher, Francesca ;
Nosavanh, LaGina ;
Lowery, Jason ;
Juracka, Amal .
JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2007, 20 (03) :209-215
[9]
Automated quantitative analysis of complex lipidomes by liquid chromatography/mass spectrometry [J].
Hermansson, M ;
Uphoff, A ;
Kakela, R ;
Somerharju, P .
ANALYTICAL CHEMISTRY, 2005, 77 (07) :2166-2175
[10]
A shotgun tandem mass spectrometric analysis of phospholipids with normal-phase and/or reverse-phase liquid chromatography/electrospray ionization mass spectrometry [J].
Houjou, T ;
Yamatani, K ;
Imagawa, M ;
Shimizu, T ;
Taguchi, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (05) :654-666