Quantitative determination of sialic acid in the monosialoganglioside, GM(1), by the thiobarbituric acid method

被引:11
作者
Mattoo, RL
Roseman, S
机构
[1] JOHNS HOPKINS UNIV,DEPT BIOL,BALTIMORE,MD 21218
[2] JOHNS HOPKINS UNIV,MCCOLLUM PRATT INST,BALTIMORE,MD 21218
关键词
D O I
10.1006/abio.1996.9987
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Several methods for the quantitative analysis of sialic acids in glycoconjugates require that the sialic acid glycosidic bond be cleaved prior to assay, The conventional (L. Svennerholm, (1958) Acta Chem. Scand. 12, 547-554) procedure for the hydrolysis of complex carbohydrates such as gangliosides employs 0.1 N H+ at 80 degrees C for 60 min, Under these conditions, we find that the monosialoganglioside (GM(1)) yields less than 50% of the total sialic acid, However, 90% recovery of sialic acid was achieved by supplementing the hydrolysis mixture with 0.2% sodium dodecylsulfate (SDS) and increasing the temperature to 85 degrees C. During hydrolysis under these conditions, N-acetylneuraminic acid (NAN) is degraded at about 7% per hour, If the analytical values for GM(1) are corrected for degradation, the recovery of NAN is essentially quantitative. (C) 1997 Academic Press.
引用
收藏
页码:30 / 33
页数:4
相关论文
共 12 条
[2]   DETERMINATION OF MONO-O-ACETYLATED N-ACETYLNEURAMINIC ACIDS IN HUMAN AND RAT SERA BY FLUOROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARA, S ;
YAMAGUCHI, M ;
TAKEMORI, Y ;
FURUHATA, K ;
OGURA, H ;
NAKAMURA, M .
ANALYTICAL BIOCHEMISTRY, 1989, 179 (01) :162-166
[3]   FLUOROMETRIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF N-ACETYLNEURAMINIC AND N-GLYCOLYLNEURAMINIC ACIDS AND ITS APPLICATION TO THEIR MICRODETERMINATION IN HUMAN AND ANIMAL SERA, GLYCOPROTEINS, AND GLYCOLIPIDS [J].
HARA, S ;
TAKEMORI, Y ;
YAMAGUCHI, M ;
NAKAMURA, M ;
OHKURA, Y .
ANALYTICAL BIOCHEMISTRY, 1987, 164 (01) :138-145
[4]  
JOURDIAN GW, 1971, J BIOL CHEM, V246, P430
[5]   DETERMINATION OF N-ACETYLNEURAMINIC AND N-GLYCOLYLNEURAMINIC ACIDS IN GLYCOCONJUGATES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
KARAMANOS, NK ;
WIKSTROM, B ;
ANTONOPOULOS, CA ;
HJERPE, A .
JOURNAL OF CHROMATOGRAPHY, 1990, 503 (02) :421-429
[6]  
LIU TY, 1972, METHOD ENZYMOL, V28, P48
[7]   HIGH-PRESSURE LIQUID-CHROMATOGRAPHY OF SIALIC ACIDS ON A PELLICULAR RESIN ANION-EXCHANGE COLUMN WITH PULSED AMPEROMETRIC DETECTION - A COMPARISON WITH 6 OTHER SYSTEMS [J].
MANZI, AE ;
DIAZ, S ;
VARKI, A .
ANALYTICAL BIOCHEMISTRY, 1990, 188 (01) :20-32
[8]   QUANTITATION OF PICOMOLE LEVELS OF N-ACETYLNEURAMINIC AND N-GLYCOLYLNEURAMINIC ACIDS BY A HPLC-ADAPTATION OF THE THIOBARBITURIC ACID ASSAY [J].
POWELL, LD ;
HART, GW .
ANALYTICAL BIOCHEMISTRY, 1986, 157 (01) :179-185
[9]  
SCHAUER R, 1987, METHOD ENZYMOL, V138, P132, DOI 10.1016/0076-6879(87)38012-7
[10]   QUANTITATIVE ESTIMATION OF SIALIC ACIDS .3. AN ANION EXCHANGE RESIN METHOD [J].
SVENNERHOLM, L .
ACTA CHEMICA SCANDINAVICA, 1958, 12 (03) :547-554