In vivo quantification of choline compounds in the breast with 1H MR spectroscopy

被引:195
作者
Bolan, PJ
Meisamy, S
Baker, EH
Lin, J
Emory, T
Nelson, M
Everson, LI
Yee, D
Garwood, M
机构
[1] Univ Minnesota, Sch Med, Ctr Magnet Resonance Res, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Med, Dept Radiol, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Sch Med, Ctr Canc, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Sch Med, Dept Med, Minneapolis, MN 55455 USA
关键词
choline; breast cancer; quantification; MRS; diagnosis;
D O I
10.1002/mrm.10654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes a methodology for quantifying levels of total choline-containing compounds (tCho) in the breast using in vivo H-1 MR spectroscopy (MRS) at high field (4 Tesla). Water is used as an internal reference compound to account for the partial volume of adipose tissue. Peak amplitudes are estimated by fitting one peak at a time over a narrow frequency band to allow measurement of small metabolite resonances in spectra with large lipid peaks. This quantitative method significantly improves previously reported analysis methods by accounting for the variable sensitivity of breast H-1 MRS measurements. Using this technique, we detected and quantified a tCho peak in 214 of 500 in vivo spectra. Who levels were found to be significantly higher in malignancies than in benign abnormalities and normal breast tissues, which suggests that this technique could be used to diagnose suspicious lesions and monitor response to cancer treatments. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:1134 / 1143
页数:10
相关论文
共 28 条
  • [1] Aboagye EO, 1999, CANCER RES, V59, P80
  • [2] External standard method for the in vivo quantification of choline-containing compounds in breast tumors by proton MR spectroscopy at 1.5 Tesla
    Bakken, IJ
    Gribbestad, IS
    Singstad, TE
    Kvistad, KA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) : 189 - 192
  • [3] Eliminating spurious lipid sidebands in 1H MRS of breast lesions
    Bolan, PJ
    DelaBarre, L
    Baker, EH
    Merkle, H
    Everson, LI
    Yee, D
    Garwood, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) : 215 - 222
  • [4] BOLAN PJ, 2001, P 87 ANN M RSNA CHIC
  • [5] Cramer-Rao bounds: an evaluation tool for quantitation
    Cavassila, S
    Deval, S
    Huegen, C
    van Ormondt, D
    Graveron-Demilly, D
    [J]. NMR IN BIOMEDICINE, 2001, 14 (04) : 278 - 283
  • [6] The evaluation of human breast lesions with magnetic resonance imaging and proton magnetic resonance spectroscopy
    Cecil, KM
    Schnall, MD
    Siegelman, ES
    Lenkinski, RE
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2001, 68 (01) : 45 - 54
  • [7] The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR
    Garwood, M
    DelaBarre, L
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) : 155 - 177
  • [8] Gribbestad IS, 1999, ANTICANCER RES, V19, P1737
  • [9] Henry PG, 1999, MAGN RESON MED, V42, P636, DOI 10.1002/(SICI)1522-2594(199910)42:4<636::AID-MRM4>3.0.CO
  • [10] 2-I