Efficacy and cardiovascular tolerability of extended dialysis in critically ill patients: A randomized controlled study

被引:177
作者
Kielstein, JT
Kretschmer, U
Ernst, T
Hafer, C
Bahr, MJ
Haller, H
Fliser, D
机构
[1] Hannover Med Sch, Dept Internal Med, Div Nephrol, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Internal Med, Div Gastroenterol Hepatol & Endocrinol, D-30625 Hannover, Germany
关键词
acute renal failure (ARF); continuous venovenous hemofiltration (CVVH); extended dialysis; intensive care unit (ICU);
D O I
10.1053/j.ajkd.2003.10.021
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Extended dialysis is an increasingly used modality of renal replacement therapy that theoretically offers advantages of both intermittent and continuous therapies in the intensive care unit (IOU). Methods We randomly treated 39 ventilated critically ill patients with oliguric acute renal failure with either continuous venovenous hemofiltration (CVVH; n = 19; age, 50.1 +/- 3.2 years; Acute Physiology and Chronic Health Assessment II [APACHE II] score, 32.3 +/- 1.2; 79% sepsis) and a substitution fluid rate of at least 30 mL/kg/h for 24 hours or with extended dialysis for 12 hours (n = 20; age, 50.8 +/- 3.6 years; APACHE II score, 33.6 +/- 1.0; 85% sepsis). The latter was performed using an easy-to-handle, single-pass, batch dialysis system. All hemodynamic parameters were monitored invasively by means of an indwelling arterial catheter. Results: Average mean arterial blood pressure, heart rate, cardiac output, systemic vascular resistance, and catecholamine dose were not significantly different in both therapies. Urea reduction rate was similar with extended dialysis compared with CVVH therapy (53% +/- 2% versus 52% +/- 3%; P = not significant) despite an average rate of substitution fluid with the latter of 3.2 +/- 0.1 L/h. This was corroborated by the finding of similar amounts of urea eliminated in the collected spent total hemofiltration and dialysis fluid. Correction of acidosis was accomplished faster with extended dialysis than CVVH, and the amount of heparin used was significantly lower with extended dialysis (P < 0.01). Conclusion: Extended dialysis combines excellent detoxification with cardiovascular tolerability, even in severely ill patients in the ICU. The technically simple dialysis system used offers flexibility of treatment time.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 24 条
[1]   Effects of bicarbonate- and lactate-buffered replacement fluids on cardiovascular outcome in CVVH patients [J].
Barenbrock, M ;
Hausberg, M ;
Matzkies, F ;
de la Motte, S ;
Schaefer, RM .
KIDNEY INTERNATIONAL, 2000, 58 (04) :1751-1757
[2]   High-volume haemofiltration in human septic shock [J].
Cole, L ;
Bellomo, R ;
Journois, D ;
Davenport, P ;
Baldwin, I ;
Tipping, P .
INTENSIVE CARE MEDICINE, 2001, 27 (06) :978-986
[3]   Studies on dialysate mixing in the Genius® single-pass batch system for hemodialysis therapy [J].
Dhondt, AW ;
Vanholder, RC ;
De Smet, RV ;
Claus, SA ;
Waterloos, MA ;
Glorieux, GL ;
Delanghe, JR ;
Lameire, NH .
KIDNEY INTERNATIONAL, 2003, 63 (04) :1540-1547
[4]  
FALTHAUSER A, 1996, INTENSIVE CARE ME S3, V22, pS364
[5]  
Kanagasundaram NS, 2003, CLIN NEPHROL, V59, P47
[6]  
Kaufman AM, 1998, J AM SOC NEPHROL, V9, P877
[7]  
Kielstein JT, 2002, CLIN NEPHROL, V57, P484
[8]   Long-term experience with an ultrapure individual dialysis fluid with a batch type machine [J].
Kleophas, W ;
Haastert, B ;
Backus, G ;
Hilgers, P ;
Westhoff, A ;
van Endert, G .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1998, 13 (12) :3118-3125
[9]   Daily dialysis in the intensive care unit [J].
Kumar, VA ;
Depner, TA .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2002, 25 (11) :1031-1033
[10]   Extended daily dialysis: A new approach to renal replacement for acute renal failure in the intensive care unit [J].
Kumar, VA ;
Craig, M ;
Depner, TA ;
Yeun, JY .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 36 (02) :294-300