Physical Activities That Cause High Friction Moments at the Cup in Hip Implants

被引:17
作者
Bergmann, Georg [1 ]
Bender, Alwina [1 ]
Dymke, Joern [1 ]
Duda, Georg N. [1 ]
Damm, Philipp [1 ]
机构
[1] Charite Univ Med Berlin, Julius Wolff Inst, Berlin, Germany
关键词
INTERSTITIAL FLUID PRESSURIZATION; POROUS-SURFACED IMPLANTS; ARTICULAR-CARTILAGE; INITIAL STABILITY; ACETABULAR COMPONENTS; BONE INGROWTH; SHEAR-STRESS; IN-VITRO; ARTHROPLASTY; DAMAGE;
D O I
10.2106/JBJS.17.01298
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Background: High friction moments in hip implants contribute to the aseptic loosening of cementless cups, of which there are approximately 100,000 cases per year; sustained joint loading may cause such high moments. The most "critical" physical activities associated with sustained joint loading were identified in this study. Methods: Friction moments in the cup were telemetrically measured about 33,000 times in the endoprostheses of 9 subjects during >1,400 different activities. The highest moments were compared with the cup's fixation stability limit of approximately 4 Nm. Results: A total of 124 different activities caused friction moments meeting or exceeding the critical limit, with the highest value of 11.5 Nm. Most involved sustained high contact forces before or during the activity. The highest peak moments (6.3 to 11.5 Nm) occurred when moving the contralateral leg during 1-legged stance, during breaststroke swimming, muscle stretching, 2-legged stance with muscle contraction, and during static 1-legged stance. The median moments were highest (3.4 to 3.9 Nm) for unstable 1-legged stance, whole-body vibration training, 2-legged stance with an unexpected push at the upper body, 1-legged stance while exercising the contralateral leg, and running after 2-legged stance. Conclusions: Frequent unloading plus simultaneous movement of the joint are required to maintain good joint lubrication and keep the friction moments low. Frequent, sustained high loads before or during an activity may cause or contribute to aseptic cup loosening. During the first months after hip arthroplasty, such activities should be avoided or reduced as much as possible. This especially applies during postoperative physiotherapy. Whether these guidelines also apply for subjects with knee implants or arthrotic hip or knee joints requires additional investigation.
引用
收藏
页码:1637 / 1644
页数:8
相关论文
共 47 条
[1]
Accardi MA, 2013, TISSUE ENG PT A, V19, P2300, DOI [10.1089/ten.TEA.2012.0580, 10.1089/ten.tea.2012.0580]
[2]
Adler E, 1992, J Arthroplasty, V7, P295, DOI 10.1016/0883-5403(92)90052-R
[3]
[Anonymous], 2014, SWEDISH HIP ARTHROPL
[5]
Australian Orthopaedic Association National Joint Replacement Registry, 2016, HIP KNEE SHOULD ARTH
[6]
Bergen H., 2016, NORWEGIAN NATL ADVIS
[7]
Standardized Loads Acting in Hip Implants [J].
Bergmann, Georg ;
Bender, Alwina ;
Dymke, Joern ;
Duda, Georg ;
Damm, Philipp .
PLOS ONE, 2016, 11 (05)
[8]
Standardized Loads Acting in Knee Implants [J].
Bergmann, Georg ;
Bender, Alwina ;
Graichen, Friedmar ;
Dymke, Joern ;
Rohlmann, Antonius ;
Trepczynski, Adam ;
Heller, Markus O. ;
Kutzner, Ines .
PLOS ONE, 2014, 9 (01)
[9]
Biologic fixation of total hip implants - Insights gained from a series of canine studies [J].
Bragdon, CR ;
Jasty, M ;
Greene, M ;
Rubash, HE ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A :105-117
[10]
The mechanobiology of articular cartilage development and degeneration [J].
Carter, DR ;
Beaupré, GS ;
Wong, M ;
Smith, RL ;
Andriacchi, TP ;
Schurman, DJ .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (427) :S69-S77