Quantitative determination of noncovalent binding interactions using automated nanoelectrospray mass spectrometry

被引:133
作者
Zhang, S
Van Pelt, CK
Wilson, DB
机构
[1] Advion Biosci Inc, Ithaca, NY 14850 USA
[2] Cornell Univ, Dept Mol Biol & Genet, Ithaca, NY 14853 USA
关键词
D O I
10.1021/ac034089d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrospray ionization mass spectrometry (ESI-MS) has proven to be an extremely powerful tool for studying biomolecular structures and noncovalent interactions. Here we report a method using a fully automated, chip-based nanoESI-MS system to determine the dissociation constants (K-d) for the complexes of two different proteins with their ligands. The automated nanoelectrospray system, consisting of the NanoMate and ESI chip, serves functionally as a combination of autosampler and nanoelectrospray ionization source. This system provides all the advantages of conventional nanoelectrospray plus automated, high-throughput analyses without carryover. The automated nanoESI system was used to investigate quantitative noncovalent interactions between ribonuclease A (RNase A) and cytidylic acid ligands (2'-CMP, CTP), a well-characterized model protein-ligand complex, and between an inactive endocellulase mutant (Thermobifida fusca Ce16A D I 17Acd) and four oligosaccharide ligands (cellotriose, cellotetraose, cellopentaose, cellohexaose). Both titration and competitive binding approaches were performed prior to automated nanoESI-MS analysis with a Q-TOF mass spectrometer. Dissociation constants for each complex were calculated from the sum of ion peak areas of free and complexed proteins during the titration and competition experiments. The measured K-d values for the RNase A-CMP and Ce16A D117Acd-G3 complexes were found to be in excellent agreement with the available published values obtained by standard spectroscopic titration techniques. To our knowledge, this is the first report of using an ESI-MS approach to study the interactions between a cellulase and oligosaccharides. The results provide new insights for understanding the nature of cellulase-cellulose interactions.
引用
收藏
页码:3010 / 3018
页数:9
相关论文
共 49 条
[1]  
Ayed A, 1998, RAPID COMMUN MASS SP, V12, P339, DOI 10.1002/(SICI)1097-0231(19980415)12:7<339::AID-RCM163>3.0.CO
[2]  
2-6
[3]   Active-site binding of glycosides by Thermomonospora fusca endocellulase E2 [J].
Barr, BK ;
Wolfgang, DE ;
Piens, K ;
Claeyssens, M ;
Wilson, DB .
BIOCHEMISTRY, 1998, 37 (26) :9220-9229
[4]   Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteins [J].
Beck, JL ;
Colgrave, ML ;
Ralph, SF ;
Sheil, MM .
MASS SPECTROMETRY REVIEWS, 2001, 20 (02) :61-87
[5]   Automated nano-electrospray mass spectrometry for protein-ligand screening by noncovalent interaction applied to human H-FABP and A-FABP [J].
Benkestock, K ;
Van Pelt, CK ;
Åkerud, T ;
Sterling, A ;
Edlund, PO ;
Roeraade, J .
JOURNAL OF BIOMOLECULAR SCREENING, 2003, 8 (03) :247-256
[6]   On-line microdialysis for enhanced resolution and sensitivity during electrospray mass spectrometry of non-covalent complexes and competitive binding studies [J].
Benkestock, K ;
Edlund, PO ;
Roeraade, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (21) :2054-2059
[7]   STUDY OF STRONG TO ULTRATIGHT PROTEIN INTERACTIONS USING DIFFERENTIAL SCANNING CALORIMETRY [J].
BRANDTS, JF ;
LIN, LN .
BIOCHEMISTRY, 1990, 29 (29) :6927-6940
[8]   Probing the nature of interactions in SH2 binding interfaces - Evidence from electrospray ionization mass spectrometry [J].
Chung, EW ;
Henriques, DA ;
Renzoni, D ;
Morton, CJ ;
Mulhern, TD ;
Pitkeathly, MC ;
Ladbury, JE ;
Robinson, CV .
PROTEIN SCIENCE, 1999, 8 (10) :1962-1970
[9]   Quantitative determination of noncovalent binding interactions using soft ionization mass spectrometry [J].
Daniel, JM ;
Friess, SD ;
Rajagopalan, S ;
Wendt, S ;
Zenobi, R .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 216 (01) :1-27
[10]   Advantages and drawbacks of nanospray for studying noncovalent protein-DNA complexes by mass spectrometry [J].
Gabelica, V ;
Vreuls, C ;
Filée, P ;
Duval, V ;
Joris, B ;
De Pauw, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (18) :1723-1728