The effect of small rotations on R2* measured with echo planar imaging

被引:8
作者
Caparelli, EC
Tomasi, D
Ernst, T
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
[2] Univ Hawaii, Honolulu, HI 96813 USA
关键词
effective transverse relaxation rate; brain rotation; susceptibility effects;
D O I
10.1016/j.neuroimage.2004.11.011
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Several modern MRI techniques, such as functional MRI (fMRI), rely on the detection of microscopic changes in magnetic susceptibility. However, differences in magnetic susceptibility between brain tissue, bone, and air also produce local magnetic field gradients that may interfere with the contrast of interest, particularly at high field strengths. Since the magnetic field distribution depends on the orientation of the human head in the MRI scanner, head rotations can change the effective transverse relaxation rate (R-2*) and confound fMRI studies. The size of the R-2* changes produced by small head rotations was estimated from a brain-shaped gel-phantom at 4 T, by measuring the signal decay at 96 different echo times. Similar measurements were carried out in a human study. Rotations larger than 2degrees changed R-2* more than 1.5 Hz in the phantom, and indicate that even small rotations may compromise fMRI results. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1164 / 1169
页数:6
相关论文
共 33 条
[1]   Modeling geometric deformations in EPI time series [J].
Andersson, JLR ;
Hutton, C ;
Ashburner, J ;
Turner, R ;
Friston, K .
NEUROIMAGE, 2001, 13 (05) :903-919
[2]  
BOWTELL R, 1994, ANN M SMR, P411
[3]   Ghost artifact reduction for echo planar imaging using image phase correction [J].
Buonocore, MH ;
Gao, LS .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :89-100
[4]   An evaluation of the use of magnetic field maps to undistort echo-planar images [J].
Cusack, R ;
Brett, M ;
Osswald, K .
NEUROIMAGE, 2003, 18 (01) :127-142
[5]   Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI Imaging [J].
Deichmann, R ;
Josephs, O ;
Hutton, C ;
Corfield, DR ;
Turner, R .
NEUROIMAGE, 2002, 15 (01) :120-135
[6]   Optimized EPI for fMRI studies of the orbitofrontal cortex [J].
Deichmann, R ;
Gottfried, JA ;
Hutton, C ;
Turner, R .
NEUROIMAGE, 2003, 19 (02) :430-441
[7]   Single-shot line scan imaging using stimulated echoes [J].
Finsterbusch, J ;
Frahm, J .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) :144-153
[8]   Movement-related effects in fMRI time-series [J].
Friston, KJ ;
Williams, S ;
Howard, R ;
Frackowiak, RSJ ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :346-355
[9]   Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts [J].
Glover, GH ;
Law, CS .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :515-522
[10]   Image distortion correction in fMRI: A quantitative evaluation [J].
Hutton, C ;
Bork, A ;
Josephs, O ;
Deichmann, R ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2002, 16 (01) :217-240