Infections associated with implantable cardioverter defibrillators placed transvenously and via thoracotomies: Epidemiology, infection control, and management

被引:78
作者
Lai, KK
Fontecchio, SA
机构
[1] Univ Massachusetts, Med Ctr, Div Infect Dis & Immunol, Sch Med,Dept Med, Worcester, MA 01655 USA
[2] Univ Massachusetts, Med Ctr, Dept Infect Control, Worcester, MA 01655 USA
关键词
D O I
10.1086/514673
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 [免疫学];
摘要
In 1993, the incidence of infection associated with implantable cardioverter defibrillators (ICDs) excluding generator, lead, and patch placements was 16.7% at our institution. Eighty-eight percent of the ICD implantations were two-staged procedures: the cardiologists performed the electrophysiologic studies in their laboratories, and implantations were performed in the operating rooms a few hours to a few days later by cardiothoracic surgeons. In 1994, both the electrophysiologic studies and ICD implantations were performed in the operating rooms without waiting periods. From 1993 to 1995, the proportion of ICDs placed transvenously increased from 56% to 100%, whereas the proportion of two-staged ICD placements decreased from 88% to zero. From 1992 to 1993 the infection rate decreased concomitantly from 16.7% to zero. From 1992 through 1995, the infection rate for implantable ICDs alone was 4.8%, and the overall infection rate for implantable ICDs (including generator, lead, and patch placements) was 6.9%, comparable to the rate reported in the literature (2.2% to 7.2%). The elimination of the two-stage procedure and the increased proportion of transvenously placed ICDs has contributed to the decrease in infection rate.
引用
收藏
页码:265 / 269
页数:5
相关论文
共 11 条
[1]
HARGROVE WC, 1989, J THORAC CARDIOV SUR, V97, P923
[2]
THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - EFFICACY, COMPLICATIONS AND SURVIVAL IN PATIENTS WITH MALIGNANT VENTRICULAR ARRHYTHMIAS [J].
KELLY, PA ;
CANNOM, DS ;
GARAN, H ;
MIRABAL, GS ;
HARTHORNE, JW ;
HURVITZ, RJ ;
VLAHAKES, GJ ;
JACOBS, ML ;
ILVENTO, JP ;
BUCKLEY, MJ ;
RUSKIN, JN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (06) :1278-1286
[3]
CLINICAL-EXPERIENCE IN 77 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR [J].
MANOLIS, AS ;
TANDEGUZMAN, W ;
LEE, MA ;
RASTEGAR, H ;
HAFFAJEE, CI ;
HUANG, SKS ;
ESTES, NAM .
AMERICAN HEART JOURNAL, 1989, 118 (03) :445-450
[4]
THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - AN OVERVIEW [J].
MIROWSKI, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :461-466
[5]
SICLARI F, 1990, PACE, V13, P547
[6]
SPRATT KA, 1993, CLIN INFECT DIS, V17, P679
[7]
INFECTION OF AN IMPLANTABLE CARDIOVERTER DEFIBRILLATOR - MANAGEMENT WITHOUT REMOVAL OF THE DEVICE IN SELECTED CASES [J].
TAYLOR, RL ;
COHEN, DJ ;
WIDMAN, LE ;
CHILTON, RJ ;
OROURKE, RA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (11) :1352-1355
[8]
AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATORS AND SURVIVAL OF PATIENTS WITH LEFT-VENTRICULAR DYSFUNCTION AND MALIGNANT VENTRICULAR ARRHYTHMIAS [J].
TCHOU, PJ ;
KADRI, N ;
ANDERSON, J ;
CACERES, JA ;
JAZAYERI, M ;
AKHTAR, M .
ANNALS OF INTERNAL MEDICINE, 1988, 109 (07) :529-534
[9]
TRAPPE HJ, 1995, BRIT HEART J, V73, P20
[10]
LONG-TERM OUTCOME WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR [J].
WINKLE, RA ;
MEAD, RH ;
RUDER, MA ;
GAUDIANI, VA ;
SMITH, NA ;
BUCH, WS ;
SCHMIDT, P ;
SHIPMAN, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1353-1361