Rapid and sensitive determination of radiocesium (Cs-135, Cs-137) in the presence of excess barium by electrothermal vaporization-inductively coupled plasma-mass spectrometry (ETV-ICP-MS) with potassium thiocyanate as modifier

被引:37
作者
Song, M [1 ]
Probst, TU [1 ]
Berryman, NG [1 ]
机构
[1] Tech Univ Munich, Inst Radiochem, D-85747 Garching, Germany
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 370卷 / 06期
关键词
D O I
10.1007/s002160000678
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrothermal vaporization-inductively coupled plasma-mass spectrometric (ETV-ICP-MS) method based on selective volatilization of cesium with KSCN as modifier has been developed for determination of radiocesium, i.e. Cs-135 and Cs-137, in the presence of isobaric barium. A 10000 times excess of barium, which was volatilized at a temperature of 1100 degreesC, resulted only in a 1% signal increase in the signal of mass 135 amu. The recommended concentration of KSCN is 0.3 mM, and pretreatment and volatilization temperatures are 400 degreesC and 1100 degreesC, respectively. A ramp time of 1 s is recommeded for the volatilization step. The achieved limit of detection for Cs-135 is 0.2 pg/mL (10 mu Bq/mL) and 4 fg (0.2 mu Bq) absolute for a sample volume of 20 muL. This means a limit of detection for Cs-137 of 0.2 pg/mL (0.6 Bq/mL) and of 4 fg (0.01 Bq) absolute. Signal variations of Cs-135 and Cs-137, respectively, in spiked samples with various matrices were investigated.
引用
收藏
页码:744 / 751
页数:8
相关论文
共 26 条
[1]  
Alonso JIG, 1996, J RADIOAN NUCL CH AR, V203, P19
[2]   CHARACTERIZATION OF SPENT NUCLEAR-FUEL DISSOLVER SOLUTIONS AND DISSOLUTION RESIDUES BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ALONSO, JIG ;
THOBYSCHULTZENDORFF, D ;
GIOVANONNE, B ;
GLATZ, JP ;
PAGLIOSA, G ;
KOCH, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1209-1215
[3]  
Berryman N, 1997, RADIOCHIM ACTA, V76, P191
[4]  
Berryman NG, 1996, FRESEN J ANAL CHEM, V355, P783
[5]   THE MEASUREMENT OF LONG LIVED RADIONUCLIDES BY NON-RADIOMETRIC METHODS [J].
BROWN, RM ;
LONG, SE ;
PICKFORD, CJ .
SCIENCE OF THE TOTAL ENVIRONMENT, 1988, 70 :265-274
[6]   Detection and quantification limits: origins and historical overview [J].
Currie, LA .
ANALYTICA CHIMICA ACTA, 1999, 391 (02) :127-134
[7]   THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[8]  
GRAY AL, 1989, APPLICATIONS INDUCTI, P1
[9]   STABILITY AND SENSITIVITY ENHANCEMENT USING ETV-ICPMS [J].
GRAY, DJ ;
WANG, S ;
BROWN, R .
APPLIED SPECTROSCOPY, 1994, 48 (11) :1316-1320
[10]  
HALL RJB, 1990, SPEC PUBL R SOC CHEM, V85, P145