Inertial cavitation produced by pulsed ultrasound in controlled host media

被引:28
作者
Deng, CX
Xu, QH
Apfel, RE
Holland, CK
机构
[1] YALE UNIV,DEPT MECH ENGN,NEW HAVEN,CT 06520
[2] UNIV CINCINNATI,COLL MED,DEPT RADIOL,CINCINNATI,OH 45267
关键词
D O I
10.1121/1.416304
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this work is to provide measurements in well-characterized media in order to better understand inertial (transient) cavitation phenomena. Focused transducers with megahertz center frequencies (2.5 MHz, 4.3 MHz) and a clinical diagnostic ultrasound system (4.0 MHz) were used to generate pulsed ultrasound to induce cavitation. An improved active cavitation detector which utilizes a highly focused transducer with much higher center frequency (30 MHz) was used to measure the threshold of inertial cavitation. In order to study the effect of the concentration of nucleation agents on cavitation thresholds, experiments were conducted in distilled water seeded with polystyrene particles. Inertial cavitation thresholds were measured for various concentrations of polystyrene particles. It was observed that the threshold decreased from 2.5 MPa at concentration of about 10(6) particles/ml to 1.6 MPa at a concentration of about 10(9) particles/ml. The effect of the concentration is not significant for smaller changes of the concentration. Measurements of the cavitation thresholds were then made in specially developed phantom materials to study the effect of viscosity on the cavitation threshold when surface tension and other mechanical properties of the materials are kept relatively constant. Experimental results show that the threshold increases with increasing viscosity, consistent with theoretical predictions. Cavitation was also detected in water seeded with polystyrene particles using a clinical ultrasound system at an acoustic pressure of 3.84 MPa. Results are comparable with those obtained in the laboratory using a 4.3-MHz focused transducer. (C) 1996 Acoustical Society of America.
引用
收藏
页码:1199 / 1208
页数:10
相关论文
共 32 条
[1]  
ALLEN J, 1994, J ACOUST SOCAM, V96, P3306
[4]   THRESHOLDS FOR CAVITATION PRODUCED IN WATER BY PULSED ULTRASOUND [J].
ATCHLEY, AA ;
FRIZZELL, LA ;
APFEL, RE ;
HOLLAND, CK ;
MADANSHETTY, S ;
ROY, RA .
ULTRASONICS, 1988, 26 (05) :280-285
[5]  
CARSON P L, 1978, Ultrasound in Medicine and Biology, V3, P341, DOI 10.1016/0301-5629(78)90076-5
[6]   ACOUSTIC CAVITATION AND THE SAFETY OF DIAGNOSTIC ULTRASOUND [J].
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (10) :597-606
[7]   BJERKNES FORCES ON BUBBLES IN A STATIONARY SOUND FIELD [J].
CRUM, LA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1975, 57 (06) :1363-1370
[8]   OUTPUT DATA FROM EUROPEAN STUDIES [J].
DUCK, FA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 :61-64
[9]   MUTUAL INTERACTION BETWEEN 2 SPHERES IN A PLANE SOUND FIELD [J].
EMBLETON, TF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1962, 34 (11) :1714-&
[10]   ON THE STABILITY OF GAS BUBBLES IN LIQUID-GAS SOLUTIONS [J].
EPSTEIN, PS ;
PLESSET, MS .
JOURNAL OF CHEMICAL PHYSICS, 1950, 18 (11) :1505-1509