Comparison of ultrasound-assisted extraction and microwave-assisted digestion for determination of magnesium, manganese and zinc in plant samples by flame atomic absorption spectrometry

被引:175
作者
Filgueiras, AV [1 ]
Capelo, JL [1 ]
Lavilla, I [1 ]
Bendicho, C [1 ]
机构
[1] Univ Vigo, Fac Ciencias Quim, Dept Quim Anlit & Alimentaria, Vigo 36200, Spain
关键词
ultrasonic extraction; plant analysis; magnesium; manganese; zinc; flame atomic absorption spectrometry;
D O I
10.1016/S0039-9140(00)00510-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a sample preparation method based on acid extraction of magnesium, manganese and zinc from plant tissue by means of high intensity probe ultrasonication is described. Acid extracts obtained upon sonication were directly nebulised into an air-acetylene flame for fast metal determination by atomic absorption spectrometry. Parameters influencing extraction such as sonication time, ultrasound amplitude, sample mass, particle size, extractant composition and volume were fully optimised. Optimum conditions for metal extraction were as follows: a 3-min sonication time, a 30% ultrasonic amplitude, a 0.1-g sample mass, a particle size less than 50 mum, a 0.3% m/v HCl concentration in the extractant solution and a 5-ml extractant volume. Six plant samples used in the human diet were analysed, the concentration range of the three metals approximately being in the range of 1500-3000 mug g(-1) for Mg, 30-735 mug g(-1) for Mn and 20-45 mug g(-1) for Zn. Limits of detection corresponding to the ultrasound-assisted extraction method were 0.10, 1.26 and 0.65 mug g(-1) for Mg, Mn and Zn, respectively. Between-batch precision, expressed as R.S.D., was about 0.5, 1.5 and 1% for Mg, Mn and Zn, respectively. Analytical results for the three metals by ultrasound-assisted extraction and microwave-assisted digestion showed a good agreement, thus indicating the possibility of using mild conditions for sample preparation instead of intensive treatments inherent with the digestion method. The advantages and drawbacks of ultrasound-assisted extraction in respect to the microwave-assisted digestion are discussed. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:433 / 441
页数:9
相关论文
共 21 条
[1]  
AGRANAT B, 1987, LIMPIEZA ULTRASONICA
[2]   Ultrasound-assisted extraction of lead from solid samples: a new perspective on the slurry-based sample preparation methods for electrothermal atomic absorption spectrometry [J].
Amoedo, L ;
Capelo, JL ;
Lavilla, I ;
Bendicho, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1221-1226
[3]  
BENDICHO C, 2000, ENCY SEPARATION SCI
[4]   Solid-liquid extraction of copper from slurried samples using high intensity probe sonication for electrothermal atomic absorption spectrometry [J].
Capelo, JL ;
Filgueiras, AV ;
Lavilla, I ;
Bendicho, C .
TALANTA, 1999, 50 (04) :905-911
[5]   Ultrasound-assisted extraction of cadmium from slurried biological samples for electrothermal atomic absorption spectrometry [J].
Capelo, JL ;
Lavilla, I ;
Bendicho, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (11) :1285-1290
[6]  
Chizzola R, 1996, J APPL BOT-ANGEW BOT, V70, P52
[7]   Critical discussion of trace element analysis of plant matrices [J].
Hoenig, M .
SCIENCE OF THE TOTAL ENVIRONMENT, 1995, 176 (1-3) :85-91
[8]  
Kubrakova IV, 1997, J ANAL CHEM+, V52, P522
[9]   Leaching of heavy metals from an aquatic plant (Lagarosiphon major) used as environmental biomonitor by ultrasonic extraction [J].
Lavilla, I ;
Perez-Cid, B ;
Bendicho, C .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1998, 72 (01) :47-57
[10]   Comparison of digestion methods for determination of trace minor metals in plant samples [J].
Lavilla, I ;
Filgueiras, AV ;
Bendicho, C .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (12) :5072-5077