Pelvic, abdominal, and chest wall reconstruction with AlloDerm in patients at increased risk for mesh-related complications

被引:203
作者
Butler, CE [1 ]
Langstein, HN [1 ]
Kronowitz, SJ [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Plast Surg, Houston, TX 77030 USA
关键词
D O I
10.1097/01.prs.0000181692.71901.bd
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The use of polypropylene mesh in the reconstruction of trunk defects increases complication rates when the mesh is placed directly over viscera or the operative site has been irradiated or contaminated with bacteria. An alternative is AlloDerm (decellularized human cadaveric dermis), which becomes vascularized and remodeled into autologous tissue after implantation. When used for fascial reconstruction, AlloDerm. forms a strong repair, causes minimal abdominal adhesions, and resists infection. Methods: We did a retrospective study of cancer patients at increased risk for mesh-related complications who underwent trunk reconstruction with AlloDerm over a I-year period. Risk factors included unavoidable placement of mesh directly over the bowel or lung, perioperative irradiation, and/or bacterial contamination of the defect. The indications, defect characteristics, reconstructive techniques, complications, and surgical outcomes were evaluated. Results: Thirteen patients were included in the study. Indications for reconstruction were oncologic resection, resection of enterocutaneous; fistula, and/or ventral hernia repair. Seven patients had bacterial contamination at the operative site and seven patients received perioperative radiation. The mean musculofascial defect size was 435 cm(2). AlloDerm was placed directly over the bowel or lung in all patients. Nine patients required flap reconstruction, including 14 pedicled and two free flaps. The mean follow-tip was 6.4 months. Complications occurred in six patients, however, there were no clinically evident mesh infections, hernias, or bulges. Conclusions: AlloDerm successfully can be used in reconstructions for large, complex pelvic, chest, and abdominal wall defects even when placed directly over viscera and when the operative field is irradiated and/or contaminated with bacteria.
引用
收藏
页码:1263 / 1275
页数:13
相关论文
共 48 条
[1]   Effects of physical barriers in prevention of adhesions: An incisional hernia model in rats [J].
Alponat, A ;
Lakshminarasappa, SR ;
Teh, M ;
Rajnakova, A ;
Moochhala, S ;
Goh, PMY ;
Chan, STF .
JOURNAL OF SURGICAL RESEARCH, 1997, 68 (02) :126-132
[2]  
Bellon JM, 1996, J AM COLL SURGEONS, V183, P11
[3]   In vitro interaction of bacteria with polypropylene/ePTFE prostheses [J].
Bellón, JM ;
G-Honduvilla, N ;
Jurado, F ;
G-Carranza, A ;
Buján, J .
BIOMATERIALS, 2001, 22 (14) :2021-2024
[4]   Ultrastructural alterations of polytetrafluoroethylene prostheses implanted in abdominal wall provoked by infection:: Clinical and experimental study [J].
Bellón, JM ;
Contreras, LA ;
Buján, J .
WORLD JOURNAL OF SURGERY, 2000, 24 (05) :528-532
[5]  
BLEICHRODT RP, 1993, SURG GYNECOL OBSTET, V176, P18
[6]   Acellular cadaveric dermis (AlloDerm): A new alternative for abdominal hernia repair [J].
Buinewicz, B ;
Rosen, B .
ANNALS OF PLASTIC SURGERY, 2004, 52 (02) :188-194
[7]  
BUTLER C, 2001, SEMIN PLAST SURG, V17, P107
[8]   Reduction of adhesions with composite AlloDerm/polypropylene mesh implants for abdominal wall reconstruction [J].
Butler, CE ;
Prieto, VG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 114 (02) :464-473
[9]  
Butler CE, 2001, J BIOMED MATER RES, V58, P75, DOI 10.1002/1097-4636(2001)58:1<75::AID-JBM110>3.3.CO
[10]  
2-A