Protein crystallography using a multilayer monochromator

被引:6
作者
Deacon, AM [1 ]
Appleby, T
Bilderback, DH
Ealick, SE
Fontes, E
Thiel, DJ
机构
[1] Cornell Univ, Dept Biochem Mol & Cell Biol, Ithaca, NY 14850 USA
[2] Cornell Univ, Wilson Lab, Cornell High Energy Synchrotron Source, Ithaca, NY 14853 USA
关键词
X-ray optics; multilayers; monochromators; macromolecular crystallography; protein crystallography;
D O I
10.1107/S0909049597017275
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A multilayer monochromator was installed on a bending-magnet beamline at the Cornell High Energy Synchrotron Source (CHESS) and was used to provide an unfocused pseudo-monochromatic X-ray beam for protein crystallography experiments. Datasets were collected from lysozyme at room temperature and human methylthioadenosine phosphorylase at 100 K. The wide energy bandpass of the multilayer allowed short exposure times, typically only a few times longer than on a focused multipole wiggler beamline. The diffraction images were processed using unmodified monochromatic data-processing software to yield datasets of good quality. These first measurements demonstrate that multilayer monochromators can be readily applied to the rapid structure determination of many typical-sized macromolecules.
引用
收藏
页码:494 / 496
页数:3
相关论文
共 12 条
[1]  
Arndt U.W., 1977, The Rotation Method in Crystallography: Data Collection from Macromolecular Crystals
[2]  
Helliwell J. R., 1992, MACROMOLECULAR CRYST
[3]   Processing of X-ray diffraction data collected in oscillation mode [J].
Otwinowski, Z ;
Minor, W .
MACROMOLECULAR CRYSTALLOGRAPHY, PT A, 1997, 276 :307-326
[4]   LAUE CRYSTALLOGRAPHY FOR STUDYING RAPID REACTIONS [J].
REN, Z ;
MOFFAT, K .
JOURNAL OF SYNCHROTRON RADIATION, 1994, 1 :78-82
[5]   CRYOCRYSTALLOGRAPHY [J].
RODGERS, DW .
STRUCTURE, 1994, 2 (12) :1135-1140
[6]   OSCILLATION PHOTOGRAPHY OF RADIATION-SENSITIVE CRYSTALS USING A SYNCHROTRON SOURCE [J].
ROSSMANN, MG ;
ERICKSON, JW .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1983, 16 (DEC) :629-636
[7]   A system for integrated collection and analysis of crystallographic diffraction data [J].
Szebenyi, DME ;
Arvai, A ;
Ealick, S ;
Laluppa, JM ;
Nielsen, C .
JOURNAL OF SYNCHROTRON RADIATION, 1997, 4 :128-135
[8]  
SZEBENYI DME, 1997, AIP C P, V417, P187
[9]   A LARGE-FORMAT HIGH-RESOLUTION AREA X-RAY-DETECTOR BASED ON A FIBEROPTICALLY BONDED CHARGE-COUPLED-DEVICE (CCD) [J].
TATE, MW ;
EIKENBERRY, EF ;
BARNA, SL ;
WALL, ME ;
LOWRANCE, JL ;
GRUNER, SM .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1995, 28 :196-205
[10]   MACROMOLECULAR CRYSTALLOGRAPHIC RESULTS OBTAINED AT CHESS USING A DETECTOR INCORPORATING A CHARGE-COUPLED-DEVICE [J].
THIEL, DJ ;
WALTER, RL ;
EALICK, SE ;
BILDERBACK, DH ;
TATE, MW ;
GRUNER, SM ;
EIKENBERRY, EF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1477-1479