Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips

被引:52
作者
Bosker, B. H. [1 ]
Ettema, H. B. [1 ]
van Rossum, M. [1 ]
Boomsma, M. F. [1 ]
Kollen, B. J. [1 ]
Maas, M. [1 ]
Verheyen, C. C. P. M. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, NL-1105 AZ Amsterdam, Netherlands
关键词
Metal-on-metal; Total hip arthroplasty; Pseudotumor; INFLAMMATORY PSEUDOTUMOR; EARLY FAILURE; ARTHROPLASTY; BEARINGS; CHROMIUM; COBALT; PAIN;
D O I
10.1007/s00402-015-2165-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The incidence and natural course of pseudotumors in metal-on-metal total hip arthroplasties is largely unknown. The objective of this study was to identify the true incidence and risk factors of pseudotumor formation in large head metal-on-metal total hip arthroplasties. Incidence, time course and risk factors for pseudotumor formation were analysed after large femoral head MoM-THA. We defined a pseudotumor as a (semi-)solid or cystic peri-prosthetic soft-tissue mass with a diameter a parts per thousand yen2 cm that could not be attributed to infection, malignancy, bursa or scar tissue. All patients treated in our clinic with MoM-THA's were contacted. CT scan, metal ions and X-rays were obtained. Symptoms were recorded. After median follow-up of 3 years, 706 hips were screened in 626 patients. There were 228 pseudotumors (32.3 %) in 219 patients (35.0 %). Pseudotumor formation significantly increased after prolonged follow-up. Seventy-six hips (10.8 %) were revised in 73 patients (11.7 %), independent risk factors were identified. Best cutoff point for cobalt and chromium was 4 mu g/l (68 and 77 nmol/l). This study confirms a high incidence of pseudotumors, dramatically increasing after prolonged follow-up. Risk factors for pseudotumors are of limited importance. Pain was the strongest predictor for pseudotumor presence; cobalt chromium and swelling were considered poor predictors. Cross-sectional imaging is the main screening tool during follow-up.
引用
收藏
页码:417 / 425
页数:9
相关论文
共 37 条
[1]
A Survey on the Prevalence of Pseudotumors with Metal-on-Metal Hip Resurfacing in Canadian Academic Centers [J].
Beaule, Paul E. ;
Kim, Paul R. ;
Powell, James ;
Mackenzie, James ;
Werle, Jason ;
Antoniou, John ;
Huk, Olga ;
Vendittoli, Pascal-Andre ;
Lavigne, Martin ;
Smith, Frank ;
Naudie, Doug ;
McCalden, Richard ;
Bourne, Robert ;
Schemitsch, Emil ;
Garbuz, Donald ;
Greidanus, Nelson ;
Duncan, Clive ;
Belzile, Etienne .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A :118-121
[2]
High incidence of pseudotumour formation after large-diameter metal-on-metal total hip replacement A PROSPECTIVE COHORT STUDY [J].
Bosker, B. H. ;
Ettema, H. B. ;
Boomsma, M. F. ;
Kollen, B. J. ;
Maas, M. ;
Verheyen, C. C. P. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (06) :755-761
[3]
Metal release from hip prostheses: cobalt and chromium toxicity and the role of the clinical laboratory [J].
Campbell, Jonathon R. ;
Estey, Mathew P. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (01) :213-220
[4]
Metal Sensitivity as a Cause of Groin Pain in Metal-on-Metal Hip Resurfacing [J].
Campbell, Pat ;
Shimmin, Andrew ;
Walter, Len ;
Solomon, Michael .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :1080-1085
[5]
Counsell A, 2008, ACTA ORTHOP BELG, V74, P870
[6]
Pseudotumors Associated with Total Hip Arthroplasty [J].
Daniel, Joseph ;
Holland, James ;
Quigley, Laura ;
Sprague, Sheila ;
Bhandari, Mohit .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (01) :86-93
[7]
Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement [J].
De Haan, R. ;
Pattyn, C. ;
Gill, H. S. ;
Murray, D. W. ;
Campbell, P. A. ;
De Smet, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1291-1297
[8]
Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs [J].
Donell, S. T. ;
Darrah, C. ;
Nolan, J. F. ;
Wimhurst, J. ;
Toms, A. ;
Barker, T. H. W. ;
Case, C. P. ;
Tucker, J. K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11) :1501-1508
[9]
CT Outperforms Radiography for Determination of Acetabular Cup Version after THA [J].
Ghelman, Bernard ;
Kepler, Christopher K. ;
Lyman, Stephen ;
Della Valle, Alejandro Gonzalez .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2362-2370
[10]
Metal-on-Metal Hip Arthroplasty in Patients Thirty Years of Age or Younger [J].
Girard, Julien ;
Bocquet, Donatien ;
Autissier, Guillaume ;
Fouilleron, Nicolas ;
Fron, Damien ;
Migaud, Henri .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (14) :2419-2426