Quantitation of cyclosporin A in whole blood by liquid chromatography/stable isotope dilution electrospray ionization mass spectrometry

被引:13
作者
Magni, F
Pereira, S
Leoni, M
Grisenti, G
Kienle, MG
机构
[1] IRCCS San Raffaele, Lab Spettrometria Massa, I-20132 Milan, Italy
[2] Poll Ind Chim SPA, Milan, Italy
[3] Univ Milan, Dipartimento Med Sperimentale Ambientale & Biotec, Milan, Italy
来源
JOURNAL OF MASS SPECTROMETRY | 2001年 / 36卷 / 06期
基金
美国国家科学基金会;
关键词
cyclosporin A; stable labelled isotope; mass spectrometry;
D O I
10.1002/jms.169
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Therapy with cyclosporin A (CsA) for immunosuppression after organ transplantation requires monitoring of its levels in blood owing to the narrow therapeutic index of the drug and to the high inter-individual variability of the drug absorption and metabolism. We describe the preparation of CsA labelled with stable isotopes (C-13 and H-2) with an isotopic enrichment of about 99% using labelled glucose and its use as internal standard for quantification of CsA blood levels by isotope dilution/electrospray ionization mass spectrometry. The method was found to be linear in the tested range (1-1000 ng) with and without the matrix. The accuracy of the bracketting calibration curves prepared using 100 ng ml(-1) labelled CsA was within +/-1.7% (bias). The results confirmed the usefulness of the procedure as a reference method for the external quality assessment of the field methods for the evaluation of CsA blood concentration, the imprecision (relative standard deviation) and accuracy (bias) being <2%. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:670 / 676
页数:7
相关论文
共 14 条
[1]   DETERMINATION OF SERUM-CHOLESTEROL BY A MODIFICATION OF THE ISOTOPE-DILUTION MASS-SPECTROMETRIC DEFINITIVE METHOD [J].
ELLERBE, P ;
MEISELMAN, S ;
SNIEGOSKI, LT ;
WELCH, MJ ;
WHITE, E .
ANALYTICAL CHEMISTRY, 1989, 61 (15) :1718-1723
[2]   COMMENTS ON SOME COMMON ASPECTS OF QUANTITATIVE MASS-SPECTROMETRY [J].
FALKNER, FC .
BIOMEDICAL MASS SPECTROMETRY, 1981, 8 (01) :43-46
[3]   Simple bioequivalence criteria: Are they relevant to critical dose drugs? Experience gained from cyclosporine [J].
Johnston, A ;
Keown, PA ;
Holt, DW .
THERAPEUTIC DRUG MONITORING, 1997, 19 (04) :375-381
[4]  
KAHAN BD, 1990, CLIN CHEM, V36, P1510
[5]   FROM IONS IN SOLUTION TO IONS IN THE GAS-PHASE - THE MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY [J].
KEBARLE, P ;
TANG, L .
ANALYTICAL CHEMISTRY, 1993, 65 (22) :A972-A986
[6]  
MAGNI F, 1992, CLIN CHEM, V38, P381
[7]   ANALYSIS OF HYDROPHOBIC PROTEINS AND PEPTIDES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
SCHINDLER, PA ;
VANDORSSELAER, A ;
FALICK, AM .
ANALYTICAL BIOCHEMISTRY, 1993, 213 (02) :256-263
[8]  
Schütz E, 1998, CLIN CHEM, V44, P2158
[9]   SELECTIVE C-13-LABELING OF CYCLOSPORINE-A [J].
SENN, H ;
WEBER, C ;
KOBEL, H ;
TRABER, R .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1991, 199 (03) :653-658