Preconcentration and separation of double-stranded DNA fragments by electrophoresis in plastic microfluidic devices

被引:75
作者
Wainright, A [1 ]
Nguyen, UT [1 ]
Bjornson, T [1 ]
Boone, TD [1 ]
机构
[1] ACLARA Biosci, Mountain View, CA 94043 USA
关键词
DNA; isotachophoresis; microfluidics; miniaturization; sample preconcentration; zone electrophoresis;
D O I
10.1002/elps.200305594
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have evaluated double-stranded DNA separations in microfluidic devices which were designed to couple a sample preconcentration step based on isotachophoresis (ITP) with a zone electrophoretic (ZE) separation step as a method to increase the concentration limit of detection in microfluidic devices. Developed at ACLARA BioSciences, these LabCard(TM) devices are plastic 32 channel chips, designed with a long sample injection channel segment to increase the sample loading. These chips were designed to allow stacking of the sample into a narrow band using discontinuous ITP buffers, and subsequent separation in the ZE mode in sieving polymer solutions. Compared to chip ZE, the sensitivity was increased by 40-fold and we showed baseline resolution of all fragments in the PhiX174/HaeIII DNA digest. The total analysis time was 3 min/sample, or less than 100 min per LabCard device. The resolution for multiplexed PCR samples was the same as obtained in chip ZE. The limit of detection was 9 fg/muL of DNA in 0.1 x polymerase chain reaction (PCR) buffers using confocal fluorescence detection following 488 nm laser excitation with thiazole orange as the fluorescent intercalating dye.
引用
收藏
页码:3784 / 3792
页数:9
相关论文
共 49 条
[1]  
[Anonymous], HDB CAPILLARY ELECTR
[2]   Analysis of oligonucleotides by on-column transient capillary isotachophoresis and capillary electrophoresis in poly(ethylene glycol)-filled columns [J].
Auriola, S ;
Jaaskelainen, I ;
Regina, M ;
Urtti, A .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3907-3911
[3]   Preconcentration and separation of antisense oligonucleotides by on-column isotachophoresis and capillary electrophoresis in polymer-filled capillaries [J].
Barmé, I ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ELECTROPHORESIS, 1998, 19 (8-9) :1445-1451
[4]  
Beckers JL, 2000, ELECTROPHORESIS, V21, P2788, DOI 10.1002/1522-2683(20000801)21:14<2788::AID-ELPS2788>3.0.CO
[5]  
2-L
[6]  
Beckers JL, 2001, ELECTROPHORESIS, V22, P3648, DOI 10.1002/1522-2683(200109)22:17<3648::AID-ELPS3648>3.0.CO
[7]  
2-Q
[8]  
Bocek P., 1988, ANAL ISOTACHOPHORESI
[9]  
Bodor R, 2002, ELECTROPHORESIS, V23, P3630, DOI 10.1002/1522-2683(200210)23:20&lt
[10]  
3630::AID-ELPS3630&gt