Randomised controlled trial of cardiotocography versus Doppler auscultation of fetal heart at admission in labour in low risk obstetric population

被引:59
作者
Mires, G [1 ]
Williams, F
Howie, P
机构
[1] Univ Dundee, Ninewells Hosp & Med Sch, Dept Obstet & Gynaecol, Dundee DD1 9SY, Scotland
[2] Univ Dundee, Ninewells Hosp & Med Sch, Dept Epidemiol & Publ Hlth, Dundee DD1 9SY, Scotland
来源
BRITISH MEDICAL JOURNAL | 2001年 / 322卷 / 7300期
关键词
D O I
10.1136/bmj.322.7300.1457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To compare the effect of admission cardiotocography and Doppler auscultation of the fetal heart on neonatal outcome and levels of obstetric intervention in a low risk obstetric population. Design Randomised controlled trial. Setting Obstetric unit of teaching hospital Participants Pregnant women who had no obstetric complications that warranted continuous monitoring of fetal heart rate in labour. Intervention Women were randomised to receive either cardiotocography or Doppler auscultation of the fetal heart when they were admitted in spontaneous uncomplicated labour. Main outcome measures The primary outcome measure was umbilical arterial metabolic acidosis. Secondary outcome measures included other measures of condition at birth and obstetric intervention. Results There were no significant differences in the incidence of metabolic acidosis or any other measure of neonatal outcome among women who remained at low risk when they were admitted in labour. However, compared with women who received Doppler auscultation, women who had admission cardiotocography were significantly more likely to have continuous fetal heart rate monitoring in labour (odds ratio 1.49, 95% confidence interval 1.26 to 1.76), augmentation of labour (1.26, 1.02 to 1.56), epidural analgesia (1.33, 1.10 to 1.61), and operative delivery (1.36, 1.12 to 1.65). Conclusions Compared with Doppler auscultation of the fetal heart, admission cardiotocography does not benefit neonatal outcome in low risk women. Its use results in increased obstetric intervention, including operative delivery.
引用
收藏
页码:1457 / 1460
页数:4
相关论文
共 23 条
[1]  
BEAULIEU MD, 1982, CAN MED ASSOC J, V127, P214
[2]   RELIABILITY AND REPRODUCIBILITY OF NONSTRESS TEST READINGS [J].
BORGATTA, L ;
SHROUT, PE ;
DIVON, MY .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1988, 159 (03) :554-558
[3]   WHAT IS THE CORRECT CESAREAN-SECTION RATE [J].
CHAMBERLAIN, G .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1993, 100 (05) :403-404
[4]   ANTENATAL CARDIOTOCOGRAM QUALITY AND INTERPRETATION USING COMPUTERS [J].
DAWES, GS ;
LOBB, M ;
MOULDEN, M ;
REDMAN, CWG ;
WHEELER, T .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (10) :791-797
[5]  
FLOREY CD, 1995, RANDOMISER
[6]   PREDICTIVE VALUE OF, AND OBSERVER VARIABILITY IN, SEVERAL WAYS OF REPORTING ANTEPARTUM CARDIOTOCOGRAPHS [J].
FLYNN, AM ;
KELLY, J ;
MATTHEWS, K ;
OCONOR, M ;
VIEGAS, O .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1982, 89 (06) :434-440
[7]  
Grant A.M, 1993, COCHRANE PREGNANCY C
[8]   FACTORS INVOLVED IN THE INTERPRETATION OF FETAL MONITOR TRACINGS [J].
HELFAND, M ;
MARTON, K .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1985, 151 (06) :737-744
[9]  
INGEMARSSON I, 1993, INTRAPARTUM FETAL SU, P45
[10]   DESCRIPTION, EVALUATION AND CLINICAL DECISION-MAKING ACCORDING TO VARIOUS FETAL HEART-RATE PATTERNS - INTEROBSERVER AND REGIONAL VARIABILITY [J].
LIDEGAARD, O ;
BOTTCHER, LM ;
WEBER, T .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1992, 71 (01) :48-53