Revision of a total hip arthroplasty with a Harris-Galante porous-coated acetabular component inserted without cement - A follow-up note on the results at five to twelve years

被引:54
作者
Lachiewicz, PF [1 ]
Poon, ED [1 ]
机构
[1] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27599 USA
关键词
D O I
10.2106/00004623-199807000-00006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fifty-seven revision total hip arthroplasties in fifty-six patients were performed with a Harris-Galante porous-coated acetabular component by one surgeon, and the patients were followed prospectively for a mean of seven years (range, five to twelve years). A trochanteric osteotomy nas performed in forty hips, and a posterior approach, with an extended anterior capsulectomy was used in the other seventeen. The acetabular defect was classified as segmental in seven hips, cavitary in twenty-three, and combined in twenty-one; six hips had no notable defect. A bulk allograft was used in eleven hips, and morseled cancellous-bone allograft or autogenous graft was used in thirty-four hips; twelve hips did not have bone-grafting. Both the femoral and the acetabular component were revised in forty-five hips, and only the acetabular component was revised in twelve, Thirty-nine hips (68 per cent) had a good or excellent clinical result according to the Harris hip score. The acetabular component was well fixed in the fourteen hips that had a fair result and the four hips that had a poor result. The acetabular component was considered to have migrated if were was a change in the angle of the cup of 5 degrees or more or a change in the horizontal or vertical position of the cup of more than three millimeters. Despite varying degrees of bone loss, no acetabular component had radiographic evidence of loosening at the latest follow-up examination. No component was revised and no revisions were scheduled. One hip was debrided for a late metastatic infection, but the component was well fixed and was not revised, There were no complications related to the use of screws for fixation, These mid-term results confirm the early success of acetabular revisions performed,vith fixation of a titanium fiber-metal-coated hemispherical component with multiple screws and no cement.
引用
收藏
页码:980 / 984
页数:5
相关论文
共 18 条
[1]   ACETABULAR RECONSTRUCTION WITH A BIPOLAR PROSTHESIS AND MORSELED BONE-GRAFTS [J].
BRIEN, WW ;
BRUCE, WJ ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (08) :1230-1235
[2]   ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[3]   RESULTS OF REVISION FOR MECHANICAL FAILURE AFTER CEMENTED TOTAL HIP-REPLACEMENT, 1979 TO 1982 - A 2 TO 5-YEAR FOLLOW-UP [J].
CALLAGHAN, JJ ;
SALVATI, EA ;
PELLICCI, PM ;
WILSON, PD ;
RANAWAT, CS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1074-1085
[4]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[5]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]  
HEEKIN RD, 1995, CLIN ORTHOP RELAT R, P184
[8]   REVISION TOTAL HIP-ARTHROPLASTY [J].
KAVANAGH, BF ;
ILSTRUP, DM ;
FITZGERALD, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (04) :517-526
[9]  
Kwong L M, 1993, J Arthroplasty, V8, P341
[10]   REVISION OF THE ACETABULUM WITHOUT CEMENT WITH USE OF THE HARRIS-GALANTE POROUS-COATED IMPLANT - 2-YEAR TO 8-YEAR RESULTS [J].
LACHIEWICZ, PF ;
HUSSAMY, OD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (12) :1834-1839