Comparison of hydro-US and spiral CT in the staging of gastric cancer

被引:25
作者
Lee, DH [1 ]
Ko, YT [1 ]
Park, SJ [1 ]
Lim, JW [1 ]
机构
[1] Kyung Hee Univ Hosp, Dept Diagnost Radiol, Dongdaemun Ku, Seoul 130702, South Korea
关键词
stomach; US; CT; neoplasms; computed tomography (CT); helical;
D O I
10.1016/S0899-7071(01)00280-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to compare the diagnostic accuracy of hydro ultrasonography (US) and spiral computed tomography (CT) in the staging of gastric cancer. Forty-three patients with gastric cancers confirmed at surgery underwent hydro-US and spiral CT on the same day prospectively. Hydro-US and spiral CT were done after ingestion of water. US and CT images were independently analyzed. After surgery, pathological findings according to TNM classification were compared with US and-CT findings. The detection rate for T1 tumors was 75% (12/16), and all T2-T4 tumors were detected (27/27). In the T class, good correlation with pathology occurred in 55.8% of cases for US and 58.1% for CT, and there was no difference in staging accuracy between US and CT (P=.7667). Overstaging occurred in 14% for US and CT. Understaging occurred in 30.2% for US and 27.9% for CT. In the N class, good correlation with pathology occurred in 60.5% for US and 55.8% for CT, and there was no difference in staging accuracy between US and CT (P=.0949). Overstaging occurred in 4.7% for US and 18.6% for CT, and understaging occurred in 34.9% and 25.6%, respectively. The diagnostic accuracy of hydro-US and spiral CT in the staging of gastric cancer was between 55.8% and 60.5%, and there was no significant difference in staging accuracy between hydro-US and spiral CT, except for a tendency to overstaging by CT and understaging by US in the N class (P < .05). (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 17 条
[1]   UPPER ABDOMINAL LYMPH-NODES - CRITERIA FOR NORMAL SIZE DETERMINED WITH CT [J].
DORFMAN, RE ;
ALPERN, MB ;
GROSS, BH ;
SANDLER, MA .
RADIOLOGY, 1991, 180 (02) :319-322
[2]   TNM staging of gastrointestinal tumors by hydrosonography: Results of a histopathologically controlled study in 60 patients [J].
Dux, M ;
Roeren, T ;
Kuntz, C ;
Richter, GM ;
Kauffmann, GW .
ABDOMINAL IMAGING, 1997, 22 (01) :24-34
[3]   Helical hydro-CT for diagnosis and staging of gastric carcinoma [J].
Düx, M ;
Richter, GM ;
Hansmann, J ;
Kuntz, C ;
Kauffmann, GW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (06) :913-922
[4]   CT of the stomach: Spectrum of disease [J].
Fishman, EK ;
Urban, BA ;
Hruban, RH .
RADIOGRAPHICS, 1996, 16 (05) :1035-1054
[5]   LYMPH-NODE METASTASES - EFFICACY OF DETECTION WITH HELICAL CT IN PATIENTS WITH GASTRIC-CANCER [J].
FUKUYA, T ;
HONDA, H ;
HAYASHI, T ;
KANEKO, K ;
TATESHI, Y ;
RO, T ;
MAEHARA, Y ;
TANAKA, M ;
TSUNEYOSHI, M ;
MASUDA, K .
RADIOLOGY, 1995, 197 (03) :705-711
[6]   Efficacy of helical CT in T-staging of gastric cancer [J].
Fukuya, T ;
Honda, H ;
Kaneko, K ;
Kuroiwa, T ;
Yoshimitsu, K ;
Irie, H ;
Maehara, Y ;
Masuda, K .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (01) :73-81
[7]   Helical CT of the stomach: Evaluation with water as an oral contrast agent [J].
Horton, KM ;
Fishman, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1373-1376
[8]   Assessment of gastric cancer: value of breathhold technique and two-phase spiral CT [J].
Hundt, W ;
Braunschweig, R ;
Reiser, M .
EUROPEAN RADIOLOGY, 1999, 9 (01) :68-72
[9]   MR imaging of advanced gastric cancer: comparison of various MR pulse sequences using water and gadopentetate dimeglumine as oral contrast agents [J].
Kim, AY ;
Han, JK ;
Kim, TK ;
Park, SJ ;
Choi, BI .
ABDOMINAL IMAGING, 2000, 25 (01) :7-13
[10]  
Lee DH, 1997, J KOREAN SOC MED ULT, V16, P33