A sequential procedure to test the progressive decrease of rare adverse events

被引:3
作者
Boelle, PY
Garnerin, P
Valleron, AJ
机构
[1] INSERM U 444, ISARS, Inst. Federatif S.-Antoine de Rech., 75571 Cedex 12, Paris, rue Chaligny
关键词
sequential test; rare events; improvement; safety;
D O I
10.1016/S0010-4825(96)00032-7
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A program to construct the Rapid Sequential Test (R-ST), a sequential procedure to test the decrease of the rate of rare adverse events, is described. This sequential procedure is constructed with the Sequential Probability Ratio method. It relies on a model for the progressive decrease in the rate of adverse events from a given initial rate to a target rate, during a transition period. The program allows one to calculate the bounds of rejection of the R-ST, and to study its power under various types of decrease. It is shown that the R-ST gives a conclusion faster than standard sequential procedures for the same type I and II error, saving at least one quarter of the trials completed during the transition period. The use of the software to construct R-STs is discussed with respect to the specification of the model. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:513 / 523
页数:11
相关论文
共 16 条
[1]   Quality assurance and prevention of immuno-hemolytic incidents in blood transfusion [J].
Boelle, PY ;
Garnerin, P ;
Hergon, E ;
Rouger, P ;
Valleron, AJ .
TRANSFUSION CLINIQUE ET BIOLOGIQUE, 1996, 3 (01) :27-34
[3]  
Grimshaw J M, 1994, Qual Health Care, V3, P45, DOI 10.1136/qshc.3.1.45
[4]  
*IEC, 1025 IEC, P1
[5]   ON SEQUENTIAL DETECTION OF A SHIFT IN THE PROBABILITY OF A RARE EVENT [J].
KENETT, R ;
POLLAK, M .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1983, 78 (382) :389-395
[6]   SYSTEMS-ANALYSIS OF ADVERSE DRUG EVENTS [J].
LEAPE, LL ;
BATES, DW ;
CULLEN, DJ ;
COOPER, J ;
DEMONACO, HJ ;
GALLIVAN, T ;
HALLISEY, R ;
IVES, J ;
LAIRD, N ;
LAFFEL, G ;
NEMESKAL, R ;
PETERSEN, LA ;
PORTER, K ;
SERVI, D ;
SHEA, BF ;
SMALL, SD ;
SWEITZER, BJ ;
THOMPSON, BT ;
VANDERVLIET, M .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (01) :35-43
[7]   IMPROVING BLOOD-TRANSFUSION PRACTICE - ROLE OF A COMPUTERIZED HOSPITAL INFORMATION-SYSTEM [J].
LEPAGE, EF ;
GARDNER, RM ;
LAUB, RM ;
GOLUBJATNIKOV, OK .
TRANSFUSION, 1992, 32 (03) :253-259
[8]   A REPORT OF 104 TRANSFUSION ERRORS IN NEW-YORK-STATE [J].
LINDEN, JV ;
PAUL, B ;
DRESSLER, KP .
TRANSFUSION, 1992, 32 (07) :601-606
[9]   CONTINUOUS INSPECTION SCHEMES [J].
PAGE, ES .
BIOMETRIKA, 1954, 41 (1-2) :100-&
[10]  
Press W.H., 1987, Numerical Recipes: The Art of Scientific Computing