Automated algorithm for the identification of joint space and phalanx margin locations on digitized hand radiographs

被引:20
作者
Duryea, J [1 ]
Jiang, Y [1 ]
Countryman, P [1 ]
Genant, HK [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
关键词
hand radiography; arthritis; segmentation; computer-aided diagnosis; joint space;
D O I
10.1118/1.598537
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rheumatoid arthritis (RA) of the hand can be characterized and assessed by the narrowing of the joint spaces which are ordinarily scored semiquantitatively by a radiologist using radiographs of the hand. Software which delineates and measures the joint spaces would be a useful tool for assessment. The first part of such an algorithm has been developed which determines the locations of the distal interphalangeal (DIP), proximal interphalangeal (PIP), and metacarpophalangeal (MCP) joint spaces for fingers 2-5 (index, middle, ring, and little) on digitized hand radiographs. In addition, points on the medial and lateral margins of each phalanx are identified which can be used as starting points for edge detection algorithms to provide segmentation of the phalanges. The algorithm is a C-language program running on a UNIX computer, uses a multiresolution approach operating, and requires approximately 10 CPU seconds per image. It was tested on a set of 54 radiographs taken from a multicenter rheumatoid arthritis study where a study protocol was followed. In addition, radiographs of individuals wearing rings and where nonanatomical structures contacted the anatomy proximal to the midpoint of the distal phalanx and distal to the MCP joint were eliminated from the data set. In order to make a quantitative assessment, regions of interest drawn by a trained radiologist were used as a gold standard. The algorithm had a success rate of 100% for the identification of each digit and over 99% for the identification of joint space locations and phalanx margins. Quantitative tests indicated excellent algorithm robustness. We have developed fully automated software which accurately identifies anatomical landmarks on digital images of the hand. (C) 1999 American Association of Physicists in Medicine. [S0094-2405 (99)00503-9].
引用
收藏
页码:453 / 461
页数:9
相关论文
共 11 条
  • [1] *AIP, EMPHYA626005903 AIP
  • [2] ALBANI S, 1997, ARTHRITIS ALLIED CON, P979
  • [3] COMPUTERIZED ASSESSMENT OF RADIOLOGICAL CHANGES OF THE HAND IN RHEUMATIC DISEASES
    ALLANDER, E
    FORSGREN, PO
    PETTERSSON, H
    SEIDEMAN, P
    [J]. SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 1989, 18 (05) : 291 - 296
  • [4] AUTOMATED SEGMENTATION OF REGIONS OF INTEREST ON HAND RADIOGRAPHS
    CHENG, SNC
    CHAN, HP
    NIKLASON, LT
    ADLER, RS
    [J]. MEDICAL PHYSICS, 1994, 21 (08) : 1293 - 1300
  • [5] DEVELOPMENT OF A NEW RADIOGRAPHIC SCORING SYSTEM USING DIGITAL IMAGE-ANALYSIS
    DACRE, JE
    COPPOCK, JS
    HERBERT, KE
    PERRETT, D
    HUSKISSON, EC
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1989, 48 (03) : 194 - 200
  • [6] Genant HK, 1998, ARTHRITIS RHEUM, V41, P1583, DOI 10.1002/1529-0131(199809)41:9<1583::AID-ART8>3.0.CO
  • [7] 2-H
  • [8] JOINT SPACE MEASUREMENT IN HAND RADIOGRAPHS USING COMPUTERIZED IMAGE-ANALYSIS
    JAMES, MF
    HEALD, G
    SHORTER, JH
    TURNER, RA
    [J]. ARTHRITIS AND RHEUMATISM, 1995, 38 (07): : 891 - 901
  • [9] SEGMENTING RADIOGRAPHS OF THE HAND AND WRIST
    MANOS, GK
    CAIRNS, AY
    RICKETS, IW
    SINCLAIR, D
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 43 (3-4) : 227 - 237
  • [10] HANDX - A MODEL-BASED SYSTEM FOR AUTOMATIC SEGMENTATION OF BONES FROM DIGITAL HAND RADIOGRAPHS
    MICHAEL, DJ
    NELSON, AC