Source strength of fungal spore aerosolization from moldy building material

被引:88
作者
Górny, RL [1 ]
Reponen, T [1 ]
Grinshpun, SA [1 ]
Willeke, K [1 ]
机构
[1] Univ Cincinnati, Dept Environm Hlth, Aerosol Res & Exposure Assessment Lab, Cincinnati, OH 45267 USA
关键词
fungal spore; release; ceiling tile; air velocity; vibration;
D O I
10.1016/S1352-2310(01)00261-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The release of Aspergillus versicolor, Cladosporium cladosporioides, and Penicillium melinii spores from agar and ceiling tile surfaces was tested under different controlled environmental conditions using a newly designed and constructed aerosolization chamber, This study revealed that all the investigated parameters, such as fungal species, air velocity above the surface, texture of the surface, and vibration of contaminated material, affected the fungal spore release. It was found that typical indoor air currents can release up to 200 spores cm(-2) from surfaces with fungal spores during 30-min experiments. The release of fungal spores from smooth agar surfaces was found to be inadequate for accurately predicting the emission from rough ceiling tile surfaces because the air turbulence increases the spore release from a rough surface. A vibration at a frequency of 1 Hz at a power level of 14 W resulted in a significant increase in the spore release rate. The release appears to depend on the morphology of the fungal colonies grown on ceiling tile surfaces including the thickness of conidiophores, the length of spore chains, and the shape of spores. The spores were found to be released continuously during each 30-min experiment. However, the release rate was usually highest during the first few minutes of exposure to air currents and mechanical vibration. About 71-88% of the spores released during a 30-min interval became airborne during the first 10 min. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4853 / 4862
页数:10
相关论文
共 40 条
[1]  
BARAN E, 1998, MED MYCOLOGY OVERVIE, P289
[2]  
Baron P.O., 1993, AEROSOL MEASUREMENT, P23
[3]  
BECKER R, 1994, AIR QUAL MG, V2, P361
[4]  
Burge H., 1999, BIOAEROSOLS ASSESSME
[5]  
BURNLETT JH, 1976, FUNDAMENTALS MYCOLOG
[6]  
Chanda S, 1996, ANN AGR ENV MED, V3, P157
[7]   Correlation between the prevalence of certain fungi and sick building syndrome [J].
Cooley, JD ;
Wong, WC ;
Jumper, CA ;
Straus, DC .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 55 (09) :579-584
[8]  
Dutkiewicz J., 1997, Annals of Agricultural and Environmental Medicine, V4, P11
[9]  
DUTKIEWICZ J, 1989, OCCUPATIONAL BIOHAZA
[10]  
FLANNIGAN B, 1994, AIR QUAL MG, V2, P3