Silver coated materials for external fixation devices:: in vitro biocompatibility and genotoxicity

被引:403
作者
Bosetti, M
Massè, A
Tobin, E
Cannas, M
机构
[1] Univ Eastern Piemonte, Dept Med Sci Human Anat, I-28100 Novara, Italy
[2] Univ Turin, Orthopaed Clin 1, CTO, I-10124 Turin, Italy
[3] Spire Corp, Bedford, MA 01730 USA
关键词
silver; external fixation; cytotoxicity; genotoxicity; biocompatibility;
D O I
10.1016/S0142-9612(01)00198-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The most significant complication in external fixation is pin tract infection causally related to the highly adaptive ability of bacteria to colonise the surfaces of "inert" biomaterials or of adjacent damaged tissue cells. The hypothesis that coating a pin with a silver-containing compound will decrease bacterial colonisation and/or pin tract infection has been confirmed in other studies in vitro and in vivo experiments. In this work, biocompatibility of silver-coated orthopaedic external fixation pins was compared with stainless steel controls in an in vitro study. Human peripheral blood lymphocytes were used to assess the possible genotoxic effect of silver, studying the frequency of sister-chromatid exchanges and micronuclei while fibroblasts (NIH 3T3) and osteoblast-like cells were used for cytotoxicity and cytocompatibility studies. These studies have shown that silver is neither genotoxic nor cytotoxic as compared to stainless steel. a material in wide use as a metal implant. At 4 days cells cultured on the silver-coated material evidenced good cell spreading and a higher cell count with respect to the uncoated material. It appears that the addition of silver onto implantable medical devices could be beneficial when specific biological properties, such as antibacterial behaviour, are required. Based on these and the previous bacterial studies it seems like the toxicity towards bacteria was quite a bit greater than that towards the human cells. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:887 / 892
页数:6
相关论文
共 21 条
[1]   A PROSPECTIVE RANDOMIZED TRIAL COMPARING THE SILVER-IMPREGNATED COLLAGEN CUFF WITH THE BEDSIDE TUNNELED SUBCLAVIAN CATHETER [J].
BABYCOS, CR ;
BARROCAS, A ;
WEBB, WR .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1993, 17 (01) :61-63
[2]   LACK OF SISTER-CHROMATID EXCHANGE INDUCTION BY POLY(METHYL METHACRYLATE BONE-CEMENT IN HUMAN-LYMPHOCYTES CULTURED INVITRO [J].
BIGATTI, MP ;
LAMBERTI, L ;
CANNAS, M ;
ROSSI, E .
MUTATION RESEARCH, 1989, 227 (01) :21-24
[3]   A COMPARISON BETWEEN CHROMIUM-51 RELEASE AND LDH RELEASE TO MEASURE CELL-MEMBRANE INTEGRITY - INTEREST FOR CYTOCOMPATIBILITY STUDIES WITH BIOMATERIALS [J].
BORDENAVE, L ;
BAREILLE, R ;
LEFEBVRE, F ;
BAQUEY, C .
JOURNAL OF APPLIED BIOMATERIALS, 1993, 4 (04) :309-315
[4]  
COLLINGE CA, 1994, ORTHOPEDICS, V17, P445
[5]   SILVER-IMPREGNATED PORCINE XENOGRAFTS FOR TREATMENT OF MESHED AUTOGRAFTS [J].
ERSEK, RA ;
DENTON, DR .
ANNALS OF PLASTIC SURGERY, 1984, 13 (06) :482-487
[6]   MEASUREMENT OF MICRONUCLEI IN LYMPHOCYTES [J].
FENECH, M ;
MORLEY, AA .
MUTATION RESEARCH, 1985, 147 (1-2) :29-36
[7]  
GINGHVI R, 1994, BIOTECHNOL BIOENG, V43, P764
[8]   BIOMATERIAL-CENTERED INFECTION - MICROBIAL ADHESION VERSUS TISSUE INTEGRATION [J].
GRISTINA, AG .
SCIENCE, 1987, 237 (4822) :1588-1595
[9]  
HU C, 1988, J TRAUMA, V28, P1488
[10]   PREVENTION OF CATHETER-ASSOCIATED URINARY-TRACT INFECTION WITH A SILVER-OXIDE COATED URINARY CATHETER - CLINICAL AND MICROBIOLOGIC CORRELATES [J].
JOHNSON, JR ;
ROBERTS, PL ;
OLSEN, RJ ;
MOYER, KA ;
STAMM, WE .
JOURNAL OF INFECTIOUS DISEASES, 1990, 162 (05) :1145-1150