Validation of a screening method for corticosteroids in doping analysis by liquid chromatography/tandem mass spectrometry

被引:68
作者
Deventer, K [1 ]
Delbeke, FT [1 ]
机构
[1] Ghent Univ, DoColab, B-9820 Merelbeke, Belgium
关键词
D O I
10.1002/rcm.1157
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A selective and sensitive method for the screening of nine corticosteroids in human urine has been validated. Analyses were performed using an ion trap instrument equipped with an electrospray ionisation (ESI) interface. All corticosteroids were separated in less than 20 min after liquid/liquid extraction with diethyl ether. The limit of detection for all substances was 4 ng/mL or lower. The method was applied to detect betamethasone after the intramuscular injection of Diprophos(R). Betamethasone could be detected for up to 12 days after administration. Validation of the chromatographic separation and mass spectrometric identification of mixtures of betamethasone and dexamethasone are also presented. Copyright (C) 2003 John Wiley Sons, Ltd.
引用
收藏
页码:2107 / 2114
页数:8
相关论文
共 19 条
  • [1] Multi-residue extraction-purification procedure for corticosteroids in biological samples for efficient control of their misuse in livestock production
    Antignac, JP
    Le Bizec, B
    Monteau, F
    Poulain, F
    Andre, F
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 757 (01): : 11 - 19
  • [2] Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry
    Bévalot, F
    Gaillard, Y
    Lhermitte, MA
    Pépin, G
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02): : 227 - 236
  • [3] DETERMINATION OF DEXAMETHASONE IN URINE AND FECES OF TREATED CATTLE WITH NEGATIVE CHEMICAL-IONIZATION - MASS-SPECTROMETRY
    COURTHEYN, D
    VERCAMMEN, J
    DEBRABANDER, H
    VANDENREYT, I
    BATJOENS, P
    VANOOSTHUYZE, K
    VANPETEGHEM, C
    [J]. ANALYST, 1994, 119 (12) : 2557 - 2564
  • [4] CUMMISKEY J, 2002, CONCERTED ACTION FIG
  • [5] Differentiation between dexamethasone and betamethasone in a mixture using multiple mass spectrometry
    De Wasch, K
    De Brabander, HF
    Van de Wiele, M
    Vercammen, J
    Courtheyn, D
    Impens, S
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 79 - 86
  • [6] EDSBACKER S, 1987, DRUG METAB DISPOS, V15, P403
  • [7] Eurachem Working Group, 1998, LAB GUID METH VAL RE
  • [8] Method for confirmation of synthetic corticosteroids in doping urine samples by liquid chromatography-electrospray ionisation mass spectrometry
    Fluri, K
    Rivier, L
    Dienes-Nagy, A
    You, CH
    Maître, A
    Schweizer, C
    Saugy, M
    Mangin, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 87 - 95
  • [9] Hardman J.G., 1996, PHARM BASIS THERAPEU
  • [10] *INT COMM, 1998, AN CRIT REP LOW CONC