Data preprocessing and partial least squares regression analysis for reagentless determination of hemoglobin concentrations using conventional and total transmission spectroscopy

被引:8
作者
Kim, YJ
Kim, S
Kim, JW
Yoon, G
机构
[1] Samsung Adv Inst Technol, Med Elect Lab, Suwon 440600, South Korea
[2] Samsung Biomed Res Inst, Biostat Unit, Seoul 135230, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Clin Pathol, Seoul 135710, South Korea
关键词
hemoglobin; partial least squares regression (PLSR); data preprocessing; visible-near infrared (visible-NIR) spectroscopy; reagentless; chemometrics;
D O I
10.1117/1.1344588
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Visible-near infrared spectroscopy was successfully used for the determination of total hemoglobin concentration in whole blood. Absorption spectra of whole blood samples, whose hemoglobin concentrations ranged between 6.6 and 17.2 g/dL, were measured from 500 to 800 nm. Two different types of transmission were measured: conventional transmission spectroscopy which collected primarily collimated radiation transmitted through the sample, and total transmission spectroscopy which used an integrating sphere to collect all scattered light as well, Different preprocessing techniques in conjunction with a partial least squares regression calibration model to predict hemoglobin concentrations were applied to the above two types of transmission, Depending on different preprocessing methods, the standard error of predictions ranged from 0.37 to 2.67 g/dL, Mean centering gave the most accurate prediction in our particular data set. Preprocessing methods designed for compensation of the scattering effect produced the worst results contrary to expectations. For univariate analysis, better prediction was achieved by total transmission measurement than by conventional transmission measurement, No significant difference was observed for multivariate analysis on the other hand, Careful selection of the data preprocessing methods and of the multivariate statistical model is required for reagentless determination of hemoglobin concentration in whole blood. (C) 2001 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 12 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]   SIMULTANEOUS MEASUREMENT OF GLUCOSE AND GLUTAMINE IN AQUEOUS-SOLUTIONS BY NEAR-INFRARED SPECTROSCOPY [J].
CHUNG, HI ;
ARNOLD, MA ;
RHIEL, M ;
MURHAMMER, DW .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1995, 50 (02) :109-125
[3]   TEMPERATURE-INSENSITIVE NEAR-INFRARED SPECTROSCOPIC MEASUREMENT OF GLUCOSE IN AQUEOUS-SOLUTIONS [J].
HAZEN, KH ;
ARNOLD, MA ;
SMALL, GW .
APPLIED SPECTROSCOPY, 1994, 48 (04) :477-483
[4]  
KOCH DD, 1999, TIETZ TXB CLIN CHEM, P321
[5]  
Kuenstner J.T., 1995, J NEAR INFRARED SPEC, V3, P11
[6]   MEASUREMENT OF HEMOGLOBIN IN UNLYSED BLOOD BY NEAR-INFRARED SPECTROSCOPY [J].
KUENSTNER, JT ;
NORRIS, KH ;
MCCARTHY, WF .
APPLIED SPECTROSCOPY, 1994, 48 (04) :484-488
[7]  
Kuenstner JT., 1994, J Near Infrared Spetrosc, V2, P59, DOI [10.1255/jnirs.32, DOI 10.1255/JNIRS.32]
[8]   Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides [J].
Pan, ST ;
Chung, H ;
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1124-1135
[9]   AN OPTICAL HEMOGLOBINOMETER FOR WHOLE-BLOOD [J].
SCHMALZEL, JL ;
STEINKE, JM ;
RANDAL, VT ;
SHEPHERD, AP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (04) :H1306-H1311
[10]   COMPARISON OF MULTIVARIATE CALIBRATION METHODS FOR QUANTITATIVE SPECTRAL-ANALYSIS [J].
THOMAS, EV ;
HAALAND, DM .
ANALYTICAL CHEMISTRY, 1990, 62 (10) :1091-1099