Influence of number and inclination angle of implants on stress distribution in mandibular cortical bone with All-on-4 Concept

被引:84
作者
Takahashi, Takeshi [1 ]
Shimamura, Ichiro [1 ]
Sakurai, Kaoru [1 ]
机构
[1] Tokyo Dent Coll, Dept Removable Prosthodont & Gerodontol, Mihama Ku, 1-2-2 Masago, Chiba, Chiba 2618502, Japan
关键词
All-on-4; Implant; Finite element analysis;
D O I
10.1016/j.jpor.2010.04.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The All-on-4 is used in the therapy of edentulous mandibles. However, few studies have investigated the effect of such implants on supporting bone. To clarify differences in stress in peri-implant cortical bone between 2-patterns of 6 implants and 8-patterns of 4 implants with change in inclination angle based on the All-on-4. Methods: Three- dimensional finite element analysis models based on the mean value of the Japanese edentulous mandible were constructed. Implants 13 or 15 mm in length were inserted between the mental foramina. In the 6-implant model, implants were inserted in parallel. In the 4-implant model, the 2 anterior implants were inserted in parallel and the 2 posterior implants in parallel or on a slant. Implants were splinted with a superstructure. A 50 N load was applied to the occlusal surface under condition A, at 2 mm distal from the distal implant, or condition B, at the distal end of the superstructure. Maximum von Mises stress on cortical bone was measured. Results: Stress was concentrated around the posterior-most implant on the right side. Under condition A, stress increased with 4 implants and increase in angulation. At 45 degrees, stress increased by 23% of that in the 6-implant model. Under condition B, stress increased with 4 implants, although stress decreased with increase in angulation. At 458, stress decreased by 45% of that in the 6 implants. Conclusions: The use of 4 implants or inclined implants increased stress on peri-implant cortical bone. However, when used in conjunction with a short cantilever, inclined implants decreased stress on peri-implant cortical bone. Crown Copyright (C) 2010 Published by Elsevier Ltd. on behalf of Japan Prosthodontic Society.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 23 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
Aparicio C, 2001, Clin Implant Dent Relat Res, V3, P39, DOI 10.1111/j.1708-8208.2001.tb00127.x
[3]  
Arataki T, 1998, Bull Tokyo Dent Coll, V39, P199
[4]   10-YEAR SURVIVAL RATES OF FIXED PROSTHESES ON 4 OR 6 IMPLANTS AD-MODUM BRANEMARK IN FULL EDENTULISM [J].
BRANEMARK, PI ;
SVENSSON, B ;
VANSTEENBERGHE, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (04) :227-231
[5]   Simplified treatment of the atrophic posterior maxilla via immediate/early function and tilted implants: A prospective 1-year clinical study [J].
Calandriello, R ;
Tomatis, M .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 :S1-S12
[6]  
Capelli M, 2007, INT J ORAL MAX IMPL, V22, P639
[7]  
Clelland N L, 1995, J Prosthodont, V4, P95, DOI 10.1111/j.1532-849X.1995.tb00323.x
[8]  
Clelland N L, 1993, Int J Oral Maxillofac Implants, V8, P541
[9]   Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses:: an in vivo study [J].
Duyck, J ;
Van Oosterwyck, H ;
Vander Sloten, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (05) :465-475
[10]  
Fugazzotto PA, 2008, INT J ORAL MAX IMPL, V23, P487