An error analysis of white matter tractography methods: synthetic diffusion tensor field simulations

被引:129
作者
Lazar, M [1 ]
Alexander, AL
机构
[1] Univ Wisconsin, Waisman Ctr, WM Keck Lab Funct Brain Imaging & Behav, Madison, WI 53705 USA
[2] Univ Wisconsin, Waisman Ctr, Dept Med Phys, Madison, WI 53705 USA
[3] Univ Wisconsin, Waisman Ctr, Dept Psychiat, Madison, WI 53705 USA
[4] Univ Utah, Dept Phys, Salt Lake City, UT 84112 USA
关键词
D O I
10.1016/S1053-8119(03)00277-5
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
White matter tractography using diffusion tensor MR images is a promising method for estimating the pathways of white matter tracts in the human brain. The success of this method ultimately depends upon the accuracy of the white matter tractography algorithms. In this study, a Monte Carlo simulation was used to investigate the impact of SNR, tensor anisotropy, and diffusion tensor encoding directions on the accuracy of six tractography algorithms. The accuracy was assessed in straight and curved tracts and tract geometries with divergence properties. In general, the tract dispersion increased with distance and decreased with SNR and anisotropy. The tract orientation with respect to the encoding scheme also influenced tract dispersion. Divergent tract geometries increased tract dispersion, whereas convergent tract geometries reduced dispersion. Analytic models of tract dispersion were constructed as a function of the tract distance, SNR, eigenvalues of the tracts, voxel size, and the relationship between the tract direction and the diffusion tensor encoding directions. In certain cases, the mean tract trajectory was found to deviate from the ideal pathway for curved trajectories. Analytical models of mean displacement were constructed as a function of the curvature, tract distance, step size, and tensor eigenvalues. These models may be used in future studies to assess the level of confidence associated with a tractography result. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:1140 / 1153
页数:14
相关论文
共 27 条
  • [1] Analysis of partial volume effects in diffusion-tensor MRI
    Alexander, AL
    Hasan, KM
    Lazar, M
    Tsuruda, JS
    Parker, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 770 - 780
  • [2] Theoretical analysis of the effects of noise on diffusion tensor imaging
    Anderson, AW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) : 1174 - 1188
  • [3] Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
  • [4] 2-O
  • [5] A simplified method to measure the diffusion tensor from seven MR images
    Basser, PJ
    Pierpaoli, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) : 928 - 934
  • [6] Basser PJ, 1996, J MAGN RESON SER B, V111, P209, DOI [10.1006/jmrb.1996.0086, 10.1016/j.jmr.2011.09.022]
  • [7] Tracking neuronal fiber pathways in the living human brain
    Conturo, TE
    Lori, NF
    Cull, TS
    Akbudak, E
    Snyder, AZ
    Shimony, JS
    McKinstry, RC
    Burton, H
    Raichle, ME
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1999, 96 (18) : 10422 - 10427
  • [8] Comparison of gradient encoding schemes for diffusion-tensor MRI
    Hasan, KM
    Parker, DL
    Alexander, AL
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (05) : 769 - 780
  • [9] LAZAR M, 2003, WHITE MATTER TRACTOG, V18, P306
  • [10] Lazar M., 2001, Proceedings of 9th ISMRM Annual Meeting, Glasgow, P506