One hundred sixteen cases of acute liver failure treated with MARS

被引:34
作者
Novelli, G [1 ]
Rossi, M [1 ]
Pretagostini, M [1 ]
Pugliese, F [1 ]
Ruberto, F [1 ]
Novelli, L [1 ]
Nudo, F [1 ]
Bussotti, A [1 ]
Corradini, S [1 ]
Martelli, S [1 ]
Berloco, PB [1 ]
机构
[1] Univ Roma La Sapienza, Policlin Umberto I, I-00161 Rome, Italy
关键词
D O I
10.1016/j.transproceed.2005.07.015
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The various definitions of acute liver failure do not accurately reflect the differences in clinical signs and prognosis. Liver support devices to improve the clinical condition before liver transplantation (LT) were used in 13 patients with primary nonfunction, 24 with fulminant hepatitis, 17 were affected by delayed nonfunction, and 56 of acute on chronic hepatic failure. The average age of these patients was 41.8 years. The average number of applications of molecular absorbing recirculating system (MARS) was about 6 (range: 1-24). The mean length of application was about 9 hours (range: 8-20). MARS treatment was carried out in HLF patients with continuous acute-on-chronic hepatic failure dialisate flow similar to continuus veno venus hemofiltration (CVVH), albumin flow < 20% of hematic flow, heparine 5110 UI/kg. In acute on cronic hepatic failure (AoCHF) patients, 6- to 11-hour (average 8.5) treatments were performed for a minimum of three treatments. The majority of patients were treated in the intensive care unit (ICU). Laboratory results were also monitored and showed progressive modification: bilirubin (before treatment 22.37 +/- 11.6 mg/dL, after treatment 11.36 +/- 7.5 mg/dL) and ammonium (before treatment 238.2 +/- 19 mu g/dL, after treatment 115.4 +/- 12 mu g/dL) showed significant change (P <.01). Lactates (before treatment 3.48 +/- 1.3 mmol/L, after treatment 1.76 +/- 1.1 mmol/L) and creatinine (before treatment 2.36 +/- 0.18 mg/dL, after treatment 1.26 +/- 0.67 mg/dL) also showed significant changes (P <.02 and P <.04). Glasgow Coma Score (GCS) went from 8.6 +/- 1.4 to 11.9 +/- 3.9 (P <.05). The mean middle celebral artery flow (V media) went from 46 cm/s/26-59 to 73 cm/s (52-106) representing decreased celebral edema, a difference that was not significant. INR scores (before treatment 2.4 after treatment 1.8) also showed no significant change. The MARS can be applied with tolerability for long periods for patients with PDF and FH as a bridge to transplant. In patients with PDF, it is used for a waiting recovery of the transplanted organ. Therefore MARS can also limit the necessity to perform further transplants.
引用
收藏
页码:2557 / 2559
页数:3
相关论文
共 11 条
[1]   Advances in bioartificial liver devices [J].
Allen, JW ;
Hassanein, T ;
Bhatia, SN .
HEPATOLOGY, 2001, 34 (03) :447-455
[2]   Hepatic encephalopathy: An update of pathophysiologic mechanisms [J].
Hazell, AS ;
Butterworth, RF .
PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1999, 222 (02) :99-112
[3]   Albumin dialysis in cirrhosis with superimposed acute liver injury: A prospective, controlled study [J].
Heemann, U ;
Treichel, U ;
Loock, J ;
Philipp, T ;
Gerken, G ;
Malago, M ;
Klammt, S ;
Loehr, M ;
Liebe, S ;
Mitzner, S ;
Schmidt, R ;
Stange, J .
HEPATOLOGY, 2002, 36 (04) :949-958
[4]   Acute-on-chronic liver failure: Pathophysiological basis of therapeutic options [J].
Jalan, R ;
Williams, R .
BLOOD PURIFICATION, 2002, 20 (03) :252-261
[5]  
LOOCK J, 1997, INT J ARTIF ORGANS, V20, P500
[6]   The systemic inflammatory response syndrome in acute liver failure [J].
Rolando, N ;
Wade, J ;
Davalos, M ;
Wendon, J ;
Philpott-Howard, J ;
Williams, R .
HEPATOLOGY, 2000, 32 (04) :734-739
[7]   Acute liver failure: Clinical features, outcome analysis, and applicability of prognostic criteria [J].
Shakil, AO ;
Kramer, D ;
Mazariegos, GV ;
Fung, JJ ;
Rakela, J .
LIVER TRANSPLANTATION, 2000, 6 (02) :163-169
[8]   Assessment of the AMC-bioartificial liver in the anhepatic pig [J].
Sosef, MN ;
Abrahamse, LSL ;
van de Kerkhove, MP ;
Hartman, R ;
Chamuleau, RAFM ;
van Gulik, TM .
TRANSPLANTATION, 2002, 73 (02) :204-209
[9]   Liver support by extracorporeal blood purification:: A clinical observation [J].
Stange, J ;
Mitzner, SR ;
Klammt, S ;
Freytag, J ;
Peszynski, P ;
Loock, J ;
Hickstein, H ;
Korten, G ;
Schmidt, R ;
Hentschel, J ;
Schulz, M ;
Löhr, M ;
Liebe, S ;
Schareck, W ;
Hopt, UT .
LIVER TRANSPLANTATION, 2000, 6 (05) :603-613
[10]  
Stange J, 1999, ARTIF ORGANS, V23, P319