A sensitive assay for the quantification of morphine and its active metabolites in human plasma and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

被引:63
作者
Clavijo, Claudia F. [1 ,2 ]
Hoffman, Keith L. [1 ]
Thomas, James J. [1 ]
Carvalho, Brendan
Chu, Larry F. [2 ]
Drover, David R. [2 ]
Hammer, Gregory B. [2 ]
Christians, Uwe [1 ]
Galinkin, Jeffrey L. [1 ,3 ]
机构
[1] Univ Colorado Denver, Clin Res & Dev iC42, Dept Anesthesiol, Aurora, CO 80045 USA
[2] Stanford Univ, Dept Anesthesia, Stanford, CA 94305 USA
[3] Childrens Hosp Denver, Aurora, CO 80045 USA
基金
美国国家卫生研究院;
关键词
Morphine; 3; beta-glucoronide; 6; beta-glucuronide; LC-MS/MS; Human plasma; Dried blood spots; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; POSTOPERATIVE PAIN; BODY-FLUIDS; MORPHINE-6-GLUCURONIDE; PHARMACOKINETICS; SERUM;
D O I
10.1007/s00216-011-4775-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Opioids such as morphine are the cornerstone of pain treatment. The challenge of measuring the concentrations of morphine and its active metabolites in order to assess human pharmacokinetics and monitor therapeutic drugs in children requires assays with high sensitivity in small blood volumes. We developed and validated a semi-automated LC-MS/MS assay for the simultaneous quantification of morphine and its active metabolites morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G) in human plasma and in dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the internal standards were the only manual steps. Morphine and its metabolites were separated on a Kinetex 2.6-mu m PFP analytical column using an acetonitrile/0.1% formic acid gradient. The analytes were detected in the positive multiple reaction mode. In plasma, the assay had the following performance characteristics: range of reliable response of 0.25-1000 ng/mL (r (2) > 0.99) for morphine, 1-1,000 ng/mL (r (2) > 0.99) for M3G, and 2.5-1,000 ng/mL for M6G. In DBS, the assay had a range of reliable response of 1-1,000 ng/mL (r (2) > 0.99) for morphine and M3G, and of 2.5-1,000 ng/mL for M6G. For inter-day accuracy and precision for morphine, M3G and M6G were within 15% of the nominal values in both plasma and DBS. There was no carryover, ion suppression, or matrix interferences. The assay fulfilled all predefined acceptance criteria, and its sensitivity using DBS samples was adequate for the measurement of pediatric pharmacokinetic samples using a small blood of only 20-50 mu L.
引用
收藏
页码:715 / 728
页数:14
相关论文
共 25 条
[1]   DETERMINATION OF MORPHINE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1987, 112 (04) :397-406
[2]   Relationships among morphine metabolism, pain and side effects during long-term treatment: An update [J].
Andersen, G ;
Christrup, L ;
Sjogren, P .
JOURNAL OF PAIN AND SYMPTOM MANAGEMENT, 2003, 25 (01) :74-91
[3]  
[Anonymous], LA4A5 CLSI
[4]  
[Anonymous], 2001, Guidance for industry: bioanalytical method validation
[5]   Determination of Morphine and 6-Acetylmorphine in Blood With Use of Dried Blood Spots [J].
Boy, Regine Garcia ;
Henseler, Joerg ;
Mattern, Rainer ;
Skopp, Gisela .
THERAPEUTIC DRUG MONITORING, 2008, 30 (06) :733-739
[6]   A BRIEF-HISTORY OF OPIATES, OPIOID-PEPTIDES, AND OPIOID RECEPTORS [J].
BROWNSTEIN, MJ .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (12) :5391-5393
[7]   Morphine metabolites [J].
Christrup, LL .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (01) :116-122
[8]   Dried Blood Spot Methods in Therapeutic Drug Monitoring: Methods, Assays, and Pitfalls [J].
Edelbroek, Peter M. ;
van der Heijden, Jacques ;
Stolk, Leo M. L. .
THERAPEUTIC DRUG MONITORING, 2009, 31 (03) :327-336
[9]   CLINICAL PHARMACOKINETICS OF MORPHINE [J].
GLARE, PA ;
WALSH, TD .
THERAPEUTIC DRUG MONITORING, 1991, 13 (01) :1-23
[10]  
GUTHRIE R, 1963, PEDIATRICS, V32, P338